Fitting the outside air intake
duct
If the appliance is installed in a room without sufficient
ventilation, you can install the connecting kit on the
appliance for the supply of outside air.
The air supply tube has a diameter of 100 mm. If
installing a smooth tube, it may be no longer than 12
m. If accessories such as bends are used, the
maximum length (12 m) must be reduced by 1 m for
each accessory used.
Outside air intake duct through the
wall or the floor and the connection
collar
1. Make a hole in the wall or the floor (refer to
Appendix 2, "Dimensions" for a suitable position
Subject to change because of technical improvements
of the hole).
2. Fit the air intake duct airtight to the wall.
3. Fit the connection collar (A) to the M6 stud (B)
using the nut (D) and the lock washer (C); see
next figure.

Building into a new hearth

The stove is installed in two stages:
Placing and connecting the stove
Building up the hearth around the stove.
Placing and connecting the stove
1. Put the appliance at the right height and level it.
2. Check that there is a clearance of 100 mm
between the existing walls, which must have the
necessary insulation (see chapter "Installation
Conditions"), and the back of the appliance; see
the next two figures.