Extinguishing The Fire; Removing Ashes - Dovre 2180CBGD Installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 62
The primary air slide controls the air flow under the
grille (1).
The secondary air slide controls the air flow in front of
the glass (air-wash) (2).
The back wall has permanent vents (3) below the
baffle plate that allow for post-combustion.
Advice
Regularly burn wood with intense roaring fires.
If you frequently have low intensity fires, tar
and creosote may be deposited in the chimney
. Tar and creosote are highly combustible
substances. Thicker layers of these
substances might catch fire when the
temperature in the chimney increases
suddenly and steeply. Therefore it is
necessary for the fire to regularly burn very
intensely, so that layers of tar and creosote
disappear.
Low intensity fires also cause tar deposits on
the stove window and door.
When the outside temperature is not very low,
it is better to burn wood intensely for a few
hours instead of having a low intensity fire for a
long period of time.
Control the air supply with the secondary air inlet.
The secondary air inlet not only supplies air to
the fire but to the glass as well, so that it does
not get dirty so quickly.
Open the primary air inlet for the time being if the air
supply by the secondary air inlet is inadequate or if
you want to fan the fire.
16
It is better to add a small amount of logs regularly
than to add many logs at the same time.

Extinguishing the fire

Do not add fuel and just let the fire go out. If a fire is
damped down by reducing the supply of air, harmful
substances will be produced and released. Therefore,
let the fire go out naturally. Keep an eye on the fire
until it has gone out. When the fire has died
completely, all air inlets can be closed.

Removing ashes

After the wood has been burnt, a relatively small
amount of ashes is left over. This bed of ashes is a
good insulating layer for the bottom of the fire
compartment and improves combustion. Therefore,
you can leave a thin layer of ashes on the bottom of
the fire compartment.
However, the air supply through the bottom of the fire
compartment must not be impeded and no ash should
be allowed to accumulate behind a cast iron inner
plate. Therefore, remove any excess ash frequently.
1. Open the door of the appliance.
2. Open the ash removal port (C); see next figure.
3. Scrape the excess ash into the ashpan (A) using
the scraper provided.
4. Using the cold hand (B) supplied, remove and
empty the ashpan.
Subject to change because of technical improvements

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2180cbc2180cbs2180cbbs

Table des Matières