Remove the squeezer tray, blade and cups simultaneously. To do so, gently unscrew
the nuts securing the cups and, using them as supports, pull outwards and they will
come loose so they can be removed easily. Unscrew the nuts of the tray shafts and
pull outwards horizontally to remove all the parts (Fig. 14).
For a very thorough clean, unscrew the balls inside the squeezer tray (Fig. 15);
underneath them there should be a washer. You can either put these parts in a
dishwasher or wash them by hand. TAKE GREAT CARE WITH THE BLADE (Fig. 3)
as it is very sharp and could cause cuts.
Z40 Self-Service Model:
-
Unscrew the nuts of the shafts of the tray and pull outwards horizontally to remove
the faucet tray and the filter (Fig. 16).
Clean the faucet tray with a cloth moistened in a neutral soapy solution
(IMPORTANT! NEVER clean it with abrasive products which might scratch it).
-
Remove the squeezer tray, blade and cups simultaneously. To do so, gently unscrew
the fastening nuts and, using them as a support, pull outwards and they will come
loose so they can be removed easily.
For a very thorough clean, unscrew the balls inside the squeezer tray (Fig. 15);
underneath them there should be a washer. You can either put these parts in a
dishwasher or wash them by hand. TAKE GREAT CARE WITH THE BLADE (Fig. 3)
as it is very sharp and could cause cuts.
Clean the front and the basket with a damp cloth.
Important Notice
In case of damage due to improper cleaning, the warranty will not apply.
Assembly
After washing and drying the components, assemble them in the following order:
1
Screw the balls into the squeezer tray. Make sure you have fitted the washers first and
TIGHTEN the balls well! Then, adjust the position of the balls as you can see in the picture,
the slots must coincide with the mark of the tray. (Fig. 17).
2
Insert the blade in the squeezer tray and slot the ribs into the grooves of the balls (Fig.
18). Check that the blade slides easily.
3
Square up the squeezer tray set and blade to their respective shafts (Fig. 19) and then
insert the cups in the squeezer tray and square them up to the shafts (Fig. 20). Assemble
this set in the machine at the same time and tighten the nuts well.
4
Fit the shafts and the pulp scraper filter in the filter, fit the filter correctly in its position in
the filter tray, self-service tray or tank (THE DRIVE SHAFT SHOULD OVERHANG THE
TRAY OR TANK) (Fig. 21a-21b-21c) and fit the set into the machine. Check that the tray
or tank is fitted properly which will also indicate that the filter is in the right position (THE
DRIVE SHAFT (Fig. 22a) SHOULD DOVETAIL WITH THE HEXAGONAL FILTER
ACTUATOR) (Fig. 22b).
5
Affix one of the side panels back on the machine (Fig. 12b).
6
Assemble the cover by attaching it to the side panel (Fig. 11).
7
Finally, affix the last side panel (Fig. 12b).
Before operating the machine, make sure that:
Juice tray and Blade are properly fitted in place.
Fastening Nuts are properly tightened.
The correct set of squeezing parts (Balls, Cups and Fruit Selector) are fitted. (see
"Accessories" in this manual).
Ensure that the side panels are properly coupled with the locking system for the
machine to operate properly.