Instructions for use for the user
12. Troubleshooting for users
Refer to Fig. 4 (page 18).
12.1. Exceeding the heating time
Problem: The sauna heater does not heat up.
Cause: After running for 6 hours, the sauna control unit automatically switches
off the sauna heater for safety reasons (heating time limit).
How to solve the problem: Follow the steps below to start up the sauna control
unit again:
1. Switch off the sauna control unit using the ON//OFF switch 7.
2. Wait 10 seconds.
3. Switch on the sauna control unit using the ON//OFF switch 7.
► The sauna control unit is operational again.
12.2. Light does not operate
How to solve the problem:
1. Switch off the sauna control unit using the ON//OFF switch 7.
2. Switch off the main fuse of the sauna control unit in the fuse box.
3. Change the bulbs used for lighting the sauna.
4. Switch the main fuse back on.
5. Press switch 7.
► If the light still does not operate, inform your supplier.
p. 24/28