SUPPLEMENTARY ELECTRIC HEATING:

The upper part of the tank can be heated quickly by using the electrical heating element. The heating element is
activated in the menu parameter "H.pump" selecting the value "EL" alone or with heat pump "HP + EL". Tmin is set to
the desired minimum temperature. When water temperature is below Tmin the heating element will support the
heating until the temperature Tmin is reached. The heating element is equipped with a safety and an operational
thermostat. The safety thermostat cuts-off when the safety level 75/85 °C is reached. If the safety lock function has
been released, your installer must reset it manually. With regard to the location of the heating element, refer to page 8.