Cooling Circuit; How Does It Work - Weider BWP 270 0A Mode D'emploi Et D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

COOLING CIRCUIT

HOW DOES IT WORK?:

Refrigerant vapours are compressed in the compressor (5) from low
pressure (6 bar) to high pres-sure (18 bar), and sent into the D-tube
condenser (7), coiled round the hot-water tank, which is colder than the
refrigerant vapours. A condensation of the refrigerant vapours takes place
and the water in the tank is heated. The refrigerant is now a liquid and
passes through the dry filter (8), which will absorb and detain residual
moisture from the refrigerant, if any. In the heat exchanger (4) a further
transfer of heat is possible. The purpose of the expansion valve (3) is to
regulate the supply of liquid to the evaporator (2). A high-pressure
sensitive switch (6) secures the cooling circuit against an inadmissible
overpressure.