5. CLEANING AND MAINTENANCE
The cleaning and maintenance operations guarantee a smooth operation of this product over time.
ATTENTION
Before cleaning, check that the stove and the connection pipes are completely cold.
For cleaning never use flammable products.
5.1 Automatic cleaning
The stove is equipped with an automatic cleaning system in stead of the manual cleaning system
Press key 6 during approximately 2 seconds and enter into the user menu.
Confirm by pressing again
Cleaning mode will be on
The 4 extraction pipes will be cleaned.
If the manual cleaning is finished 600 seconds before the automatic cleaning, press key 1 to interrupt the
process and return to the user menu.
5.2 Smoke outlet cleaning and maintenance
INFORMATION
A good smoke evacuation system (connections and ducts) is a safety guarantee for the room and the correct
operation of your stove.
We recommend frequent and regular cleaning according to written instructions given by the installer and/or
manufacturer of the installed material (required by law to submit this documentation) and according to current standards.
The smoke evacuation duct must be checked regularly and be cleaned by experienced staff, before first ignition or
after a long period of non-use.
5.3 Stove cleaning and maintenance
Cleaning and maintenance operations guarantee a good performance and safety to the product over time. Maintenance must
be done according to the consumption (we recommend performing maintenance after you have used the stove and burned
18 kg of pellets) and always once a year.
You need to program technical interventions for the maintenance with the technical service support which will have to provide
you with a certificate of conformity for each revision.
Avoid leaving residues of pellet in the stove during non use periods
A correct cleaning of the stove is essential for its proper functioning.
List of the cleaning and maintenance main operations to be carried out by technical assistance:
Cleaning of fan, extractor and environmental fans
Cleaning of all inaccessible places by the user, as well as the fireplace
Verifying the dispenser status
Verification of the turning on as well as the pellet load
Control and change of door joint
Remove door gasket and clean the union fitting located at the entrance of the smoke
Parameters control and combustion control.
Intervention declaration certifying the maintenance performance
ATTENTION
Do not perform cleaning and maintenance tasks without assuring that the stove is completely cold.
Washing