WARNING
The manufacturer rejects all responsibility in case the described control and utilization norms are not respected.
4. OPERATION
4.1 Safety information
• Due to the temperatures given off by the stove, adults and children must pay special attention and not touch its surface.
Special care must be taken with the children.
• It is prohibited to throw water or any other substance on the stove when it is in operation or during the cooling phase, in
order to avoid thermal shock.
• Do not deposit anything next to the stove which is flammable or sensitive to heat
4.2 Combustible
The only combustible which can be used is the pellet.
In order to guarantee combustion without problems, it is necessary that the pellet remains completely dry. We
recommend you use a good quality pellet, compact and floury. Ask your distributor for the appropriate pellet type. Store
the pellet at a minimum distance of 1.5 meters from the stove. (See Chapter 5)
ATTENTION
The stove has been designed to work only with original and quality pellet.
The manufacturer declines all responsibility in the case of using low quality pellet and a not adequate diameter
which may cause a malfunction.
4.3 Safety device
Thermocouple: located in the exhaust smoke pipe which increases the temperature. According to the established
parameters, you can control the power phase by turning on and switching off.
Electromagnetic device: placed in the smoke evacuation duct, it blocks the stove operation when the fire door is
opened or when the tube is blocked.
Safety thermostat: positioned below the hopper loader, intervenes in the case in which the temperature exceeds
the preset security level, block and pellet loading the heater shuts off.
Safety Thermostat: is located in the power supply. Intervenes in the case the indoor temperature is greater than the
safety value, blocking the supply of pellets and shutting down the stove automatically.
4.4 Operation
Before turning on the stove, the verification of the following points is required:
Deposit must be loaded with pellet. To load it, the top lid must be opened
The combustion chamber must be clean.
Check the door hermetic seal
Check that the power cord is properly connected to the power supply before pressing the switch.
During the first 2-3 ignitions one should pay attention to the following points:
No children must be present during ignition as some gases emitted may be toxic to health. Adults should also
avoid prolonged presence beside the stove. It is obligatory to ventilate the stove during the first hours of
operation.
Ventilate the stove in the first performances.
This product must be never use as a waste incinerator.