NO
ATTENTION
Ensure that Community regulations or the competent health services in the territory or do not obligate the
application of additional standards.
For installation in a building, authorization from the community of owners must be requested
3.8 End part of installation. Chimney outlet
The chimney is placed at the end of the pipe and its function is:
•
Evacuate the combustion residues to the exterior.
•
Avoid the entrance of rain or other objects into the smoke evacuation pipe
•
Guarantee the combustion even if it is windy.
The top of the chimney must meet the following criteria:
•
The interior section must be equal to the one from the smoke evacuation pipe
•
The output section can not be less than twice the inside measures of the duct
•
Must be built in a way that prevents the entry of rain, snow... inside the smoke evacuation pipe even in case of wind
•
Must be easily removed for cleaning as well as for periodic revisions.
•
Installation of smoke evacuation must be aesthetic and in harmony with the building
•
Must be properly placed to ensure a right dispersion of particles from combustion
There must not be obstacles within a radius of 10 meters from the chimney, for instance a wall, a tree... In the case that
obstacles exist, the chimney pipe must be placed at least 1 meter above the obstacle.
3.9 Connection to the power supply
Stoves require connection to power supply. Our stoves are equipped with a power supply cable adapted for medium
temperatures. To change the cable it is necessary to contact the product manufacturer or a technical service centre.
Before making the electrical connection one must ensure that:
•
The electrical installation characteristics are the ones indicated on the stove plate.
•
The plug area where the stove will be plugged has an earth connection according to the current standards. Earth
connection (for security) is obligatory by law. Failure to comply with this point will result in the loss of the product
guarantee.
•
The power cord must never reach temperatures higher than 75ºC
.
Contact a qualified electrician if you want to connect the product directly to the net.
If the product is not used for a long time, unplug it from the wall outlet or turn off the switch.
If the unit is connected through a power cord to the socket, this must be easily accessible when the unit is installed in
accordance with the instruction manual. If the device is not connected to the power cable through a cable and a plug but
directly to the net, you must install a device that guarantee the disconnection from the net.
116
YES
.