Troubleshooting
2. Move the push bar to the forward position.
See Section "Empty sweeping container" in
Chapter 7.7 of this operating manual.
3. Disconnect the blue battery connection lead
from battery. See Section "Disconnect battery
leads" in Chapter 10.2 of this operating
EN
manual.
4. Remove the cover (1) from the hinges (2)
carefully by tapping gently with the palm of
one's hand against the edge of the cover in
the direction of the arrow.
3
4
Fig. 19: Remove the switch plate
5. Pull the switch plate (3) carefully upwards from
the pilot pins (4).
6. Place the switch plate (3) with the connected
leads to one side.
56
4
Fig. 20: Fuse F1
7. Remove the F1 fuse (5) from the fuse holder
(6).
8. Check the fuse and, if necessary, replace.
» The picture to the right shows a blown fuse.
» Use only 15 amp fuses.
» Reassembly is carried out in reverse order.
The following must be taken into account:
1. Place the cover on top and then snap it into
place by carefully pressing it in the hinges.
2. Plug the blue battery lead well into the
insertion flap of the battery.
3. Switch the sweeping machine on by switching
the on/off switch to the I position.
4. Check whether the device is working again as
usual.
NOTE
If the fuse blows immediately after the
sweeping machine has been switched on
again, contact service department.