Site Preparation
Electrical Requirements
Installation must comply with all applicable electrical
codes and be properly grounded (earthed).
International models from the factory designed without a
transformer require a 220-240 V AC, 50/60 Hz electrical
supply, fused at the correct rating for the unit. If required
by local or national codes, the power cord can be easily
replaced using the power inlet device.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause
interruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240 V AC, 50/60 Hz
Service
Receptacle
grounding-type (earthed)
178
E
mm
152
mm
1918 mm
FROM FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location
4 | English
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify
the outlet is properly grounded.
WARNING
Do not locate multiple portable socket-outlets,
power strip, or portable power supplies at the rear of
the appliance.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
10 amp
WARNING
If the supply cord is damaged, it must be replaced by
a special cord or assembly available from the manu-
facturer or its service agent.
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions
Plumbing Requirements
Installation must comply with all applicable plumbing
codes.
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with installation of
the anti-tip bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 2.4–8.3 bar supplied to the
unit at all times. A copper line is not recommended for this
application.
PLUMBING REQUIREMENTS
Water Supply
6.4 mm OD copper, braided
stainless steel or PEX tubing
Pressure
2.4–8.3 bar
(240–830 kPa)
Excess Line for Connection
RIGHT SIDE
OF OPENING
152
132
mm
mm
76 mm
13 mm
AREA EXTENDS
FORWARD ON FLOOR
Water supply location
Preparation
Uncrate the unit, and inspect for damage. Remove the
wood base, and discard the shipping bolts and brackets.
Remove and recycle packing materials. Do not discard the
kickplate, anti-tip bracket, and hardware.
Completely retract the front leveling legs to allow the unit
to be moved into position. The front and rear leveling legs
can be adjusted from the front once the unit is in position.
Remove the drain pan from the base of the unit to avoid
damage and to allow for proper placement of the appli-
ance dolly.
The grille assembly should be removed prior to moving the
unit. To remove, rotate the bottom of the grille upward.
Disconnect the network cable, then remove the center
mounting screw. Loosen the three grille bolts from the
grille, then pull the grille forward. Refer to the illustrations
below.