- LAYOUT
J8
J1
BUZZER
J1 => CONNECTOR FOR CONNECTIONS TO THE CONTROL PANEL SAFETY INPUTS
Green wire
=> safety strip EDGE 2
- If JP2 is set to the LEFT => this output enables the safety strips stored in 4-5-6 positions.
- If JP2 is set to the RIGHT => this output is not enabled.
Gray wire => contact common COM
Yellow wire => safety strip EDGE 1
- If JP2 is set to the LEFT => this output enables the safety strips stored in 1-2-3 positions.
- If JP2 is set to the RIGHT => this output enables the safety strips stored from 1 to 6
positions.
Black wire => photocell PHOT N.C.
White wire => terminal for connecting the wire coming from the system control button N.O.
Brown wire => auto test power feed A+ TEST.
J2 =>
CONNECTOR FOR CONNECTIONS TO THE 12/24V ac/dc CONTROL PANEL
AT THE BLINKER OUTPUT (CHECK POLARITY)
Red wire =>
positive (connects to the positive pole of the blinker output)
Black wire => negative (connects to the negative pole of the blinker output)
J4 =>
TERMINALS FOR CONNECTIONS TO THE 120/230V BLINKER OUTPUT OF
CONTROL PANEL
J5 => TERMINAL FOR CONNECTIONS TO CONTROL PANEL
J8 => TERMINAL FOR CONNECTION TO THE ANTENNA 868,3 MHz
JP1 => A+ TEST
-
Jumper selection AUTOTEST mode for control panels with AUTOTEST negative
power feed
+/~
Jumper selection AUTOTEST mode for control panels with AUTOTEST positive/
alternate power feed
JP2 => If JP2 is set to the LEFT
- EDGE 1 output enables the safety strips stored in 1-2-3 positions
- EDGE 2 output enables the safety strips stored in 4-5-6 positions
If JP2 is set to the RIGHT
- EDGE 1 output enables the safety strips stored from 1 to 6 positions
- EDGE 2 output is not enabled.
WARNING: after moving the jumper with RX MASTER Wi-Fi powered, press the S1 button
fot 7 times to activate the change of the position of JP2 jumper.
S1
SW1
J5
4 3 2 1
4
3
Total opening
COM
12/24V ac/dc
control contact
COM-K BUTT/START
K.BUTTON
SW1 => DIP-switches for pairing and identifying strips and photocells
S1 => PROG. RX Programming button
BUZZER => Sound signal for installation, warning and alarm status
LED
DL1 (red)
DL2 (red)
DL3 (red)
DL4 (red)
DL5 (green)
DL6 (yellow)
LED EDGE PHOT
off
green
red/green
LED EDGE PHOT 1 - EDGE SENSOR OR PHOTOCELL 1
LED EDGE PHOT 2 - EDGE SENSOR OR PHOTOCELL 2
LED EDGE PHOT 3 - EDGE SENSOR OR PHOTOCELL 3
LED EDGE PHOT 4 - EDGE SENSOR OR PHOTOCELL 4
LED EDGE PHOT 5 - EDGE SENSOR OR PHOTOCELL 5
LED EDGE PHOT 6 - EDGE SENSOR OR PHOTOCELL 6
SW1 MICRO-SWITCHES - DIP
DIP 1 ON => STRIP SENSOR OR PHOTOCELL 1 ACTIVATED
DIP 2 ON => STRIP SENSOR OR PHOTOCELL 2 ACTIVATED
DIP 3 ON => STRIP SENSOR OR PHOTOCELL 3 ACTIVATED
DIP 4 ON => STRIP SENSOR OR PHOTOCELL 4 ACTIVATED
DIP 5 ON => STRIP SENSOR OR PHOTOCELL 5 ACTIVATED
DIP 6 ON => STRIP SENSOR OR PHOTOCELL 6 ACTIVATED
ATTENTION: Every time is made a change of dip switches settings, press PROG RX push-
At the end the leds EDGE PHOT must be turned off.
18
Dual-color Led
JP1
JP2
EDGE PHOT 1-6
2+
1-
-
+
Power feed
12/24V ac/dc
- strip contact N.C. (EDGE 2)
- strip contact N.C. (EDGE 1)
- photocell contact N.C. (PHOTO)
- total opening command with push-button N.O. in the system
- available for future implementations
- electrical power indicator 12-24V ac/dc
=> operating normally
=> safety strip or photocell engaged
=> alarm
botton for 6 times to update the system.
J4
J2
12/24V ac/dc