Télécharger Imprimer la page

RIB RX MASTER Wi-Fi Mode D'emploi page 21

Fiche de gestion système sans fils

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Note: if removing the battery and commanding the door to open the buzzer on RX MASTER
Wi-Fi does not sound, DIP 3 is OFF on the RX MASTER Wi-Fi (safety not enabled). Turn it ON.
CMO Wi-Fi STRIP ALARM SIGNAL CHECK
Check that by taking the battery out of the transmitter with DIP 3 ON (for example), LED
EDGE PHOT 3 flashes red while LED DL2 turns off, and that buzzer emits every 3 seconds
a tone for 1 minute.
Repeat the check for any other strips installed.
Note: if the battery is removed and the buzzer on the MASTER Wi-Fi does not sound, DIP 3
is OFF on RX MASTER Wi-Fi (safety not enabled). Turn it to ON.
WARNING (replace the batteries almost empty)
The WARNING informs the user to replace the batteries immediately.
When battery power reaches 2,3V for NOVA Wi-Fi and 3V for CMO Wi-Fi, these safeties
signal to RX MASTER Wi-Fi the low battery status and RX MASTER Wi-Fi activates the buzzer
with a sound every 3 seconds for 1 minute.
The warning is renewed for 1 minute if a new command is received.
The LED EDGE PHOT paired to the photocell or the strip with the low batteries, emits a
steady red light.
The system is still operational, but it is better to replace the batteries as soon as possible in
order to avoid a full stop of the door operation which happens when the batteries reach 2V
for NOVA Wi-Fi/VERTIGO Wi-Fi and 2,7 V for CMO Wi-Fi.
ALARM (batteries empty or safety damaged)
The alarm activates when the batteries are empty (2V for NOVA Wi-Fi/VERTIGO Wi-Fi and
2,7V for CMO Wi-Fi) or when a safety is damaged.
On RX MASTER Wi-Fi the LEDs DL1, DL2 and DL3 turn off and RX MASTER Wi-Fi blocks
the automation.
On MASTER Wi-Fi the LED EDGE PHOT paired with the photocell or the strip damaged, or
with the low batteries, flashes red. The BUZZER emits a sound every 3 seconds for 1 minute,
notifying the user to change the batteries or call a technician to repair the safety.
The alarm is renewed for 1 minute if a command is given to the door.
REPLACING THE BATTERIES
The lifespan of the 1.5 V AA batteries used in the safety devices is about 3 years.
In case it is required to replace the batteries, it will not be necessary to re-program the
devices.
- Identify the safety device with empty batteries by checking LEDs EDGE PHOT.
- Use the number of LED EDGE PHOT which is flashing red or that emits a steady red light,
identify the number of the safety device with batteries empty.
- Find the NOVA Wi-Fi or CMO Wi-Fi devices with the yellow sticker bearing the identification
number corresponding to the number of the LED EDGE PHOT which is in alarm status on
the RX MASTER Wi-Fi.
- Replace the batteries, checking that the polarity is correct.
- Press push button PROG TX on the NOVA Wi-Fi or CMO Wi-Fi to restart the RX MASTER
Wi-Fi.
- The buzzer of the RX MASTER Wi-Fi will turn off and the LEDs DL1-DL2-DL3 (if in alarm
status) will turn on. The LED EDGE PHOT corresponding to the safety device with the new
batteries will turn off.
The automation is now ready to restart.
ATTENTION: Please remember that batteries must be disposed properly according to current
standards. In case of disposal of the safety devices, please remember to remove the AA
batteries and dispose them properly
PROCEDURE TO DELETE ALL RECORDED SAFETY DEVICES
To delete all safety devices recorded in the RX MASTER Wi-Fi memory, just push and hold
the button PROG. RX for 10 seconds.
After 10 seconds all LEDs EDGE PHOT will flash 6 times, indicating successful removal.
Afterwards LED EDGE PHOT and LEDs DL1, DL2 and DL3 will turn off.
ATTENTION: WITH LED DL1, DL2 AND DL3 OFF, AUTOMATION DOES NOT WORK.
PROCEDURE TO DELETE A SINGLE SAFETY DEVICE
In order to remove a single safety device, use the following procedure:
- Push PROG. RX one or more times to select the LED EDGE PHOT, to select the safety device
to delete, which begins flashing green.
- After selecting the safety device, push and hold the button PROG. RX for 10 seconds.
- After 10 seconds LED EDGE PHOT flashes red/green 6 times, indicating successful
removal.
ATTENTION: Place the DIP EDGE PHOT paired to the deleted safety device in OFF, then
scan all LEDs EDGE PHOT pushing the button PROG. RX 6 times.
IMPORTANT: Remove batteries from the deleted safety device.
TECHNICAL SPECIFICATIONS
- POWER
- APPLICABLE TENSION ON CONTACT J4
- APPLICABLE TENSION ON CONTACT J2
- ABSORPTION AT REST
- MAXIMUM ABSORPTION
- WORKING TEMPERATURE
- SIZE
- WEIGHT
SAFETY DEVICES RADIO SIGNAL
TECHNICAL SPECIFICATIONS
- FREQUENCY
- SENSITIVITY
- EMITTING POWER
- MODULATION TYPE
- RANGE
21
12/24 Vac/dc
120/220/230V 50/60Hz
12/24V ac/dc
40 mA
100 mA
-20°C ÷ +60°C
125x55x28 mm
0,090 kg
868,3 MHz
-108 dBm
<25 mW
FSK
20 m in open spaces
G
B

Publicité

loading

Ce manuel est également adapté pour:

Acg6152