G
B
VERTIGO Wi-Fi 8
VERTIGO Wi-Fi 10
The Wi-Fi System complies with the standard EN 13849-2:2015 and together with a
electronic control panel with AUTOTEST is a PL "c" Category 2 protection device.
RX MASTER Wi-Fi card manages NOVA Wi-Fi and VERTIGO Wi-Fi photocells and CMO
Wi-Fi strips which also attach to the moveable panel without the need for a cable
collector.
RX MASTER Wi-Fi steadyly monitors the presence of the various safety devices and the
status of the batteries, satisfying completely the need of an active safety for all types of
openings.
Using the correct electronic control panels it is possible for the system to perform an auto
test as required by EN12453:2017.
Each radio-controlled safety device has its own internal identification code which
distinguishes it from the others.
REFERENCE STANDARDS FOR AUTOMATIC DOORS AND GATES
The installer must ensure that the Wi-Fi System is connected as specified by the standard EN
12453:2017 point 5.1.2 to an electronic control panel capable of performing an operations
check before closing (AUTO TEST).
Therefore, the use of DFM devices permits system installation in compliance with current
Standards and Directives.
Once machine installation is complete it must be ascertained that it complies with standard
EN 13241:2016.
DFM may not be held responsible for any damage caused by improper, wrong or
unreasonable use of the product.
MASTER Wi-Fi
This is the heart of the system: it runs all of the control (433,92 MHz), safety and signaling
(868,3 MHz) devices programmed in the installation phase.
NOVA Wi-Fi
SAFETY DEVICES
RX MASTER Wi-Fi can manage up to 6 safety devices at the same time.
- NOVA Wi-Fi photocells: a mechanical strip or a resistive strip can be connected to both
the photocell transmitter and the photocell receiver.
- VERTIGO Wi-Fi photocells (VERTIGO Wi-Fi 8 - VERTIGO Wi-Fi 10): wireless vertical
photocells substituting the sensitive edge.
- CMO Wi-Fi strip (code ACG3016), with built-in transmitter/receiver.
COMMANDS
It is possible to connect a wired controls with N.O. contact (key selectors, push-buttons...).
SOUND SIGNALS
RX MASTER Wi-Fi has a buzzer which signals installation phases, a warning if the batteries
are low or exhausted, an alarm in case of failure of one of the safety devices.
16
CMO Wi-Fi