4) With a slotted screwdriver turn the choking screw (see figure 15) and, while observing the flame at the same time
through the cooker porthole, evaluate the consistency of the flame so it remains on when switching quickly from the
MINIMUM to the MAXIMUM position.
WARNING: The above-mentioned adjustment should be made only with methane gas burners, while for those
operating with liquid gas the screw must be locked at the end in a clockwise direction. The grill
burner always operates at maximum and therefore no minimum adjustment is required.
The electric connection must comply with the current legal standards and regulations.
Before making the connection, check that:
- The system electrical rating and the current outlets are adequate for the maximum power output of the appliance (see
the label applied to the bottom of the casing).
- The outlet or the system is equipped with an efficient ground connection in accordance with the current legal standards
and regulations. The company will not be responsible for the non-compliance with these instructions.
When the connection to the power supply network is made using an outlet:
- If the power cord is supplied without a plug, apply a standard plug that is suitable for the load indicated on the label.
Connect the wires according to the diagram shown in FIG.16 and check that:
letter L (phase) = brown wire;
letter N (neutral) = blue wire;
ground symbol
= green-yellow wire;
- The power cord must be positioned so that an overtemperature of 75 K will not be reached at any point.
- Do not use reductions, adapters or splitters since they might cause false contacts and lead to dangerous overheating.
When the connection is made directly to the electric network:
Use a device that ensures disconnection from the mains in which the contacts are opened to a distance that
-
permits complete disconnection according to the conditions for over-voltage category III.
- Remember that the ground wire must not be interrupted by the circuit-breaker.
- As an alternative, the electric connection can also be protected by a high-sensitivity residual current circuit-breaker.
- It is highly recommended to attach the special green-yellow ground wire to an efficient ground system.
WARNING: If the power cord is replaced, the ground wire (yellow-green) connected to the terminal, should be
longer than the other wires by about 2 cm.
TABLE N°3 : TYPES OF POWER CORDS
OVEN OPERATION
GAS OVEN / GAS GRILL
GAS OVEN/
ELECTRIC GRILL
ELECTRIC OVEN
ATTENTION: By placing the
of European safety, health and environmental requirements stated in the legislation for this product.
Before performing any maintenance operation, disconnect the appliance from the gas supply and electricity
network.
To replace parts such as knobs and burners, just remove them from the seats without disassembling any part of the
cooker.
To replace parts such as nozzle supports, valves and electric components follow the procedure described in the burner
adjustment paragraph. To replace the valve or the gas thermostat, it is also necessary to disassemble the two rear gas
train brackets, loosening the 4 screws (2 per bracket) that attach it to the rest of the cooker and, unscrew the nuts that
attach the front burner valves to the control support, after removing all the knobs. To replace the gas or electric
thermostat, also disassemble the rear cooker guard, loosening the relative screws, to be able to pull out and reposition
the thermostat bulb.
To replace the oven bulb, just unscrew the protection cap that projects out inside the oven. (Fig.17)
WARNING: Before replacing the bulb, disconnect the appliance from the electric power supply.
WARNING: The power cord supplied with the appliance is connected to that appliance with an X type connection (in
compliance with standards EN 60335-1, EN 60335-2-6 and subsequent amendments) for which it can be installed without
the use of special tools, with the same type of cord as the one installed.
APPLIANCE ELECTRIC CONNECTION:
WORK SURFACE OPERATION
ONLY GAS BURNERS
GAS BURNERS + 1 HOT PLATE
GAS BURNERS + 2 HOT PLATES
ONLY GAS BURNERS
GAS BURNERS + 1 HOT PLATE
GAS BURNERS + 2 HOT PLATES
ONLY GAS BURNERS
GAS BURNERS + 1 HOT PLATE
GAS BURNERS + 2 HOT PLATES
marking on this product, we declare, on our own responsibility, compliance to all
APPLIANCE MAINTENANCE
REPLACING PARTS
21
CROSS SECTION
3 X 0.75 mm²
3 X 1 mm²
3 X 1 mm²
3 X 1 mm²
3 X 1,5 mm²
3 X 2,5 mm²
3 X 1,5 mm²
3 X 2,5 mm²
3 X 2,5 mm²