PART - 6.
BEFORE CALLING YOUR AFTER SALES SERVICE
Check Warnings;
Your fridge warns you if the temperatures for cooler and freezer are in improper levels or
when a problem occurs in the appliance. Warning codes are displayed in the Freezer and
Cooler Indicators.
ERROR TYPE
SR
SR – Set value
blink on freezer
set value screen
SR – Set value
Blink on cooler
set value screen
SR – Set value
blink on freezer
and cooler set
value screen
SR – Set value
blink on cooler
set value screen
"--"
ERROR TYPE
"Failure
Warning"
Freezer comp. Not
Cold enough
"Refrigerator comp.
Not Cold enough"
"not cold enough
Warning"
Refrigerator comp.
too Cold
"Low voltage
Warning"
WHY
There is/are some
part(s) Out of order
or there is a failure in
cooling process
This caution will be
seen especially after
long term of power
failure
Ideal temperature for
Ref. Compartment is
+4
C. If you see this
o
warning your foods
have risk of spoiling.
It is combination of
"not cool enough"
error for both of the
compartments.
The foods starts to
freeze because of
the too much cold
temperature
When the power supply
gets lower than 170 V
the appliance gets to
steady position.
EN -21-
WHAT TO DO
Call Service for assistance as
soon as possible.
1. Do not freeze the foods
that are thaw and use in
short time period.
2. Set the freezer
temperature to colder values
or set the super freeze , until
the compartment gets to
normal temperature.
3. Do not put fresh food until
this failure is off.
1. Set the refrigerator
temperature to colder values
or set the super cooling
mode until the compartment
gets to normal temperature.
2. Do not open the door
much until this failure is off.
You will see this failure when
first starting the appliance.
It will be off after the
compartments gets normal
temperature
1. Check if the "Super cooling
mode" is on
2. Decrease the refrigerator
temperature values
This is not a
failure. This
prevents any damages on
the compressor. This warning
will off after the voltage gets
required level

Publicité