PARAMETER
Max. allowed
up to 90 °C when pumped 5 minutes
temperature of the
max.
fluid
Max. room
50 °C
temperature
pH
4-10
7. REMOTE CONTROL BOX
DESCRIPTION
Pump control and monitoring box integrated into a
compact plastic housing, for 1 or 2 pumps, with possibility
of manual activation.
• Voltage: 1 ~ 220-240 V AC
• Frequency: 50-60 Hz
• IP rating: IPX4
• Analog level sensor, Input voltage 0-5 V
• 4 m cable
• Dimensions, see page 6.
OPERATION
Yellow LED :
mains supply
Red LED :
alarm
Manual activation :
Motor 1
Manual activation :
Motor 2
The yellow LED is lit when the device is switched on.
Pressing the button
pump
to
forced
GENERAL ALARMS
Mains alarm:
In case of power failure (or when unplugging the device):
the buzzer is triggered, Sanicubic 2 GR HP S: + the red
alarm LED lights up + the yellow mains LED flashes.
Level alarm:
If the water level inside the device is abnormally high:
the buzzer is triggered + the red alarm LED lights up
+ both motors start-up (Sanicubic 2 GR HP S). If this
LED flashes red, it indicates a detection problem for the
normal water level.
Time alarm:
If the motor (or one of the two motors for
Sanicubic 2 GR HP S) runs for more than 1 minute: the
buzzer is triggered + the red alarm LED lights up + the
other motor starts-up (Sanicubic 2 GR HP S).
General alarm reset
If the problem that triggered an alarm above disappears,
the buzzer stops, but the red alarm LED remains on until
the next normal cycle.
One of the two keypad keys will stop the buzzer in any
that caused the alarm has been resolved. The alarms of
the remote box also remain active until the problem has
been solved. This prevents the system from being «aban-
doned» in default.
OPTION OF CONNECTION TO AN EXTERNAL
ALARM (SANICUBIC 2 GR HP S)
Option of externalising the alarm signal. Dry contact (no
voltage) NO (normally open) operated by a relay.
VALUE
switches the corresponding
operation.
Max. 250 V / 16A
External alarm
Dry contact NO
8. WIRED ALARM BOX
DESCRIPTION
The wired alarm box reproduces the alarm signal from
the remote control box.
The alarm box does not require a separate power supply.
The power is supplied through the Control box. In case of
power failure, the alarm unit's battery takes over.
•
• IP 2X
• 5 m alarm cable
• Dimensions: see page 6
OPERATION
Red LED :
alarm
1/ The red general alarm LED reproduces the operation
of the corresponding LED on the control box. The alarm
unit sounds as long as the fault is present. To stop the
alarm, press the reset (*) button under the alarm unit.
2/ The yellow «mains» LED indicates the power supply
status of the alarm unit :
- steadily glowing light = live Sanicubic GR HP S
connected to the mains supply
- flashing = power failure on the Sanicubic GR HP S.
3/ The alarm box can be completely switched off by a
long press on the reset button (*).
9. INSPECTION AND MAINTENANCE
DISCONNECT ELECTRICAL POWER BEFORE WORKING
DANGER
Work performed on the pumping station
by unqualified staff.
Repairs
performed by specially trained staff.
INSPECTION
The proper running of the wastewater lifting station must
be checked by user once a month observing at least two
starting cycles.
MAINTENANCE
The lifting station has to be regularly maintained by a
• Every 3 months for lifting stations installed in commer-
cial premise,
16
Alarm contact can be con-
nected to a powered sys-
tem. This contact closes
as soon as the station is in
alarm mode (except in the
case of area alarm) and re-
mains closed as long as the
alarm sounds.
See Wiring diagrams page
55.