EN
DISPOSAL
The device must not be disposed of as
household waste and must be disposed of at a
recycling point for electrical equipment. The
device's
materials
reusable.
The
electronic waste, recycling and recovery of any
form of used appliances contribute to the preservation
of our environment.
3. DESCRIPTION
AREA OF APPLICATION
Sanicubic GR HP S is a lifting pump for wastewater
originating from WC (black water), sinks, clothes washing
machines, dishwashers, showers or baths and basins,
used in private or commercial applications (restaurants,
hairdressings salons,...).
Sanicubic GR HP S can pump out hot water.
The unit has a high performance level, and is safe and
reliable, provided all the rules for installation and mainte-
nance in this notice are strictly followed.
Unauthorised pumped fluids:
The following liquids and substances are banned:
- Solid materials, fibres, tar, sand, cement, ash, coarse
paper, hand towels, wipes, cardboard, rubble, rubbish,
slaughterhouse waste, oils, greases, etc.
- Wastewater
containing
example, untreated greasy waste from restaurants).
Pumping these liquids and substances requires the fitting
of a compliant grease trap, in accordance with EN1825.
- Rain water.
Do not dispose of concentrated chemical products (ac-
ids, solvents, bases, oxidants, reducers, etc.) into sani-
tary ware connected to the Sanicubic GR HP S. Only the
discharge of diluted products, followed by rinsing with
clean water, may be allowed in exceptional cases.
OPERATING PRINCIPLE
Sanicubic GR HP S 1 contains 1 pump.
Sanicubic GR HP S 2 contains two independent pumps.
Both pumps operate alternately to ensure even ware. In
case of surcharge operation, both motors run simultane-
ously (or if one pump fails, the other takes over).
The tank is equipped with two dip tubes, one to control
the motor activation and the other for the alarm system.
TECHNICAL DATA
SANICUBIC
Type
Maximum vertical
pumping height
Maximum Flow rate
Voltage
Frequency
Maximum power
consumption
Maximum current
consumption
Electrical class
Mode of operation
Max. temperature of the
pumped fluid 5 min/h
Useable volume
Inlet diameter
2 x Øext 100 mm
Discharge diameter
and
components
disposal
of
electrical
harmful
substances
1 GR HP S
2 GR HP S
R150
18 m
19 m
/h
3
220-240 V
50-60 Hz
2 500 W
5 000 W
10 A
20 A
I
S3 25%
S3 40%
90 °C
12 L
15 L
2 x Øext 100
mm
1 x Øext
50/100 mm
1 x Øext 50 mm
SANICUBIC
Ventilation diameter
Type of impeller
are
Material
and
Pump housing
Motor housing
Shaft
Tank
Impeller
SCOPE OF SUPPLY See attached leaflet.
PUMP CURVE See attached leaflet.
DIMENSIONS See page 6.
4. INSTALLATION
The Sanicubic GR HP S installation must comply with
EN 12056-4 standards. All work to install the equipment,
put it into service and carry out maintenance must be
done by a qualified professional specialist.
See also attached leaflet.
FITTING
• The space in which Sanicubic GR HP S is installed must
be large enough to leave at least 600 mm around the
unit for easy maintenance. This space must be well lit,
ventilated, and must never be immersed in water and
must be protected from frost.
(for
• Isolation valves (not supplied) should be fitted to the
inlet pipework and discharge pipework to isolate the
unit in case of the need for service.
• This discharge pipe must be designed so as to prevent
Note: unless otherwise stated locally, the back-flow level
corresponds to the level of the road or pavements,...
• The pumping station must always be ventilated so that
the tank is always at atmospheric pressure. The ventila-
to a mechanically controlled ventilator.
• The alarm signal is always visible to the user. If neces-
sary, use an external alarm contact switch (see 7.4 Option
of connection to an external alarm (Sanicubic 2 GR HP S))
or the wired alarm box.
FITTING
Fit the pumping station on the bare ground and level it
with a spirit level.
it to the ground using the mounting kit provided.
HYDRAULIC CONNECTION
DANGER
The pumping station must not be used as
a control point for piping.
Prop up the pipes upstream from the
pumping station. Make connections without
constraints.
Use suitable means to compensate for
thermal expansion of the piping.
4.3.1 Inlet
IMPORTANT
It is recommended that you mount check valves and stop
valves on the inlet pipes. These must be mounted so that
they do not hinder disassembly of the pumping station.
• Choose the connection openings to use.
• Cut the tip of the corresponding boss with a saw.
14
1 GR HP S
2 GR HP S
1 x Øext 50 mm
Grinder
PA 12 GF
Aluminium
Stainless steel
PE HD
PPO GF
-