SFA SANICONDENS Instructions D'installation Et De Maintenance
SFA SANICONDENS Instructions D'installation Et De Maintenance

SFA SANICONDENS Instructions D'installation Et De Maintenance

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

249
1
12.10
IND1
IMPORTANT
DO NOT RETURN ANY MERCHANDISE TO THE VENDOR
NE PAS RETOURNER DE MARCHANDISE AU VENDEUR
For customer Service, Returns or Technical Questions, please call Saniflo's Technical support toll-free at
800-571-8191 (USA) or 800-363-5874 (CDN).
Pour le service client, les retours ou toute question technique, merci d'appeller le service technique de Saniflo
au numéro suivant : 800-571-8191 (USA) or 800-363-5874 (CDN).
The user should retain these instructions for future reference • A lire attentivement et à conserver à titre d'information
This product must be installed in strict accordance whith local plumbing codes.
Product should be installed by a qualified technician.
Le produit doit être installé dans le respect des réglements sanitaires locaux.
Le produit doit être installé par un technicien qualifié.
US
CDN
FR
INSTALLATION AND MAINTENANCE INSTRUCTIONS
INSTRUCTIONS D'INSTALLATION ET DE MAINTENANCE

Publicité

loading

Sommaire des Matières pour SFA SANICONDENS

  • Page 1 12.10 IND1 IMPORTANT DO NOT RETURN ANY MERCHANDISE TO THE VENDOR NE PAS RETOURNER DE MARCHANDISE AU VENDEUR For customer Service, Returns or Technical Questions, please call Saniflo’s Technical support toll-free at 800-571-8191 (USA) or 800-363-5874 (CDN). Pour le service client, les retours ou toute question technique, merci d’appeller le service technique de Saniflo au numéro suivant : 800-571-8191 (USA) or 800-363-5874 (CDN).
  • Page 2 20 Ft (6 m) 5-5/8" (143 mm) 9-1/2" (242 mm) max 15 Ft (4.5 m) 12 Ft (4 m) 9 Ft (3 m) 6 Ft (2 m) 3 Ft (1 m)
  • Page 3 15 Ft (4.5 m) max. SANICONDENS ® CD10 110-115 V - 60 Hz - 60 W IP20 - S3 15% T=160° F...
  • Page 4 Type CD10 person. The unit should be connected to a fully grounded Max. vertical pumping 15 Ft (4.5 m) electrical supply. The SANICONDENS ® requires a 120V Maximum flow rate (gal / hour) 86 (326 l/h) single phase AC 60 Hz supply.
  • Page 5 This includes products eligible bear the designation NTRL. NTRL (Nationally Recognized Testing Laboratory) is a desi- This SFA appliance bears a 3 year warranty starting from gnation awarded by the American Occupational Safety and the date of purchase, subject to proper installation and use, Health Administration (OSHA) to laboratories authorized to in compliance set out in this notice.
  • Page 6 En particulier les indications repérées par : « » indication avertissant de la présence d’un risque RACCORDEMENT A L’ÉVACUATION d’origine électrique, L’évacuation du SANICONDENS ® doit être « » instructions réservées exclusivement aux profession- impérativement réalisée avec le tuyau flexible d'une nels qualifiés.
  • Page 7 L’intensité maximale admissible par notre système de détection est de 0.5A. Pour toutes interventions, débrancher la prise de courant Afin de protéger la partie électrique du SANICONDENS ® , une fois l’alarme activée, l’eau continuant de remplir la cuve sera ANOMALIE CONSTATÉE...