Heater Name
Heater name is defined during the heater connection
and setup. It can be changed anytime from the heater
settings.
Exit Heater
Press X to close heater view and return to heater's list.
Heater Settings
The 3-dot icon opens heater settings.
Use this option to edit the parameters defined during
heater configuration.
POOL-SPA page
Displays the page to control the operation mode and
water temperature target.
ACCESSORIES page
Displays the page to control heater accessories.
Operation Mode selector
This 3-button selector can be used to change the
operation mode in the heater.
Use OFF option to stop heating. In this mode the
heater is operational but is maintained in standby until
mode changes to POOL or SPA.
Use POOL or SPA mode to set a water temperature
target.
POOL and SPA mode use an independent temperature
target for each mode.
Pool mode selector is enabled in Heat/Cool models.
Heater Status
This display shows the current operational status of
heater.
No Demand is displayed when the unit is in OFF mode
or when Water Temperature is equal or above the
temperature target.
Heating is displayed when the unit is heating. In Heat/
Cool models, Cooling is displayed when pool cool or
pool auto is selected and the unit is cooling.
56
APPROVED
Water Temperature
Setpoint or Target Temperature
Setpoint slider selector
Pool and Spa size
Pool and Spa estimated Heat up time
UNCONTROLLED DOCUMENT IF PRINTED
The water temperature measured by the heater is
displayed in this field.
The water temperature setpoint display and selector
shows the water temperature target.
Heater start to heat when Water Temperature is 1
degree Fahrenheit or more, below the setpoint and
operation Mode is POOL or SPA.
Heat/Cool models, Pool Cool mode: Heater starts to
cool when water temperature is 1F or more above the
setpoint.
Heat/cool models, Pool Auto mode: Heater starts to
cool when water temperature is above the temperature
setpoint + cooling deadband. Heater start to heat
when Water Temperature is 1 degree Fahrenheit or
more, below the setpoint
The setpoint slider can be used to make quick changes
to the water temperature target.
Selection can be fine-tuned with the [+] and [-] buttons
in the setpoint display and selector.
The Pool and Spa size displays shows the size
selected in the configuration of the heater when
connected to Raymote.
These parameters can be updated from the Heater
Settings page.
These fields displays an estimated heat up time
based in the provided Pool and Spa size, the current
water temperature, the water target temperature and
ambient temperature.
Technical restrictions apply to this estimation.