Main View
The main view of Raymote display a list of the heaters
added in to your Raymote Organization.
Each heater is represented by a tile with its name and
an overview of the heater operation parameters.
Heater Name
Heater name is defined during the heater connection
and setup, but it can be changed anytime from the
heater settings.
Water Temp
The water temperature measured by the heater is
displayed in this field. Water Temp variates with the
ambient temperature, pumps and heater's operation.
Setpoint
Setpoint is the goal temperature for the heater. It can
be adjusted from the Crosswind V control board or
directly from Raymote.
Heater start a call-for-heat when Water Temp is 1
degree Fahrenheit or more, below the setpoint and
operation Mode is POOL or SPA.
In heat/cool models, Pool cool mode, heater starts to
cool when water is 1°F above temperature setpoint.
In heat/cool models, Pool auto mode, heater starts to
cool when water temp is above temperature setpoint
+ cooling deadband. In this mode, unit call-for-heat if
water temperature is 1°F below temperature setpoint.
52
USER AND ORGANIZATION
SETTINGS
HEATER NAME
Crosswind V Heat Pump
CURRENT WATER
TEMPERATURE
HEATER OFFLINE
INDICATOR
HEATERS SCREEN
Figure 84. Main View - Heaters List
UNCONTROLLED DOCUMENT IF PRINTED
APPROVED
Raymote organization list can handle 1 or multiple
Commercial
and
equipped with Raymote. See Figure 84.
ADD HEATERS AND
SORTING
WATER TEMPERATURE
TARGET
HEATER MODE
SELECTION
HEATER LIST CAN
INCLUDE COMMERCIAL
HEATERS
OPENS AUTOMATION
SCREEN
OPENS NOTIFICATIONS
SCREEN
Heater terminates heat when Water Temp is equal or
greater the setpoint temperature, or when Mode is
changed to OFF.
Mode
Mode field displays the current operation mode
selected.
POOL mode use an independent setpoint. Heat/
Cool models include POOL COOL and POOL AUTO
modes.
SPA and TIMED SPA modes use an independent
setpoint.
In OFF mode the heater is operational but is
maintained in standby until mode changes to POOL
or SPA.
Offline Indicator
The offline indicator is displayed only when the heater
can not be detected online.
Offline status can be cause by a heater disconnected
from power, WiFi signal weak or not available, or due
to any change in WiFi signal name or password.
Check the Connectivity Troubleshooting section for
details on how to recover or reconnect a heater to
Raymote.
Residential
Raypak
heaters