All manuals and user guides at all-guides.com
Ingersoll-Rand No. 50
Ingersoll-Rand No. 100
Always use an air line lubricator with these tools.
We recommend the following Filter-Regulator-Lubrica-
tor (FRL) Unit:
To Air
System
To Air
Tool
Emergency
Shut-Off
Valve
Model
Handle
Drive
Impacts
I.D.
Type
in
bpm
244A
1/2 sq.
1/2 sq.
pistol
1,300
with
244A-2
extended
anvil
Tested in accordance with PNEUROP PN8NTC1.2
■
♦ Tested in accordance with ISO8662-7
•
Tested in accordance with ISO3744
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and the parts be separaed by material so that they can be recycle.
LUBRICATION
Inside USA use FRL unit #C28-04-FKG0-28
Outside USA use FRL unit #C28-C4-FKG0
After each forty-eight hours of operation, or as experi-
ence indicates, inject about 4 cc of the recommended
grease into the Grease Fitting (3).
INSTALLATION
Main Line(s) Inner Ø
Branch Line(s) Inner Ø
to be 3X Size of
to be 2X Size of
Air Tool's Inlet Ø
Air Tool's Inlet Ø
R
L
F
Lubricator
Regulator
Filter
FRL
Drain Regularly
SPECIFICATIONS
■ Sound Level
Recommended
Torque Range
dB (A)
ft•lb (N•m)
Pressure
(40-350)
96
(54-474)
3
Compressor
(Dwg. TPD905-2)
Inlet
♦ Vibrations
Connection
Level
(Thread)
• Power
2
m/s
NPT
109
5.5
1/4
Minimum
Inside Ø (Air
Hose)
in (mm)
3/8 (10)