Télécharger Imprimer la page

Selco Saber 70 chp Manuel D'instructions page 43

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 79
For the maintenance or replacement of torch components
and/or earth cables:
Check the temperature of the component and
make sure that they are not overheated.
Always use gloves in compliance with the safety
standards.
Use suitable wrenches and tools.
Failure to carry out the above maintenance will invalidate all
warranties and exempt the manufacturer from any liability.
6 TROUBLESHOOTING
The repair or replacement of any parts in the
system must be carried out only by qualified
personnel.
The repair or replacement of any parts in the system by unau-
thorised personnel will invalidate the product warranty.
The system must not be modified in any way.
The manufacturer disclaims any responsibility if the user
fails to follow these instructions.
The system fails to come on (green LED off)
Cause
No mains voltage at the socket.
Solution
Check and repair the electrical system as needed.
Use qualified personnel only.
Cause
Faulty plug or cable.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sy-
stem repaired.
Cause
Line fuse blown.
Solution
Replace the faulty component.
Cause
Faulty on/off switch.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sy-
stem repaired.
Cause
Connection between wire feed carriage and gene-
rator incorrect or faulty.
Solution
Check that the various parts of the system are prop-
erly connected.
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sy-
stem repaired.
No output power (the system does not weld/cut)
Cause
Faulty torch trigger button.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sy-
stem repaired.
All manuals and user guides at all-guides.com
Cause
The system has overheated (temperature alarm -
yellow LED on).
Solution
Wait for the system to cool down without switching
it off.
Cause
Side cover open or faulty door switch.
Solution
In order to ensure safe operation the side cover
must be closed while welding/cutting.
Replace the faulty component.
Contact the nearest service centre to have the
torch repaired.
Cause
Incorrect earth connection.
Solution
Earth the system correctly.
Read the paragraph "Installation ".
Cause
Mains voltage out of range (yellow LED on).
Solution
Bring the mains voltage within the power source
admissible range.
Connect the system correctly.
Read the paragraph "Connections ".
Cause
Faulty contactor.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sy-
stem repaired.
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sy-
stem repaired.
Incorrect output power
Cause
Incorrect selection in the welding/cutting process
or faulty selector switch.
Solution
Select the welding/cutting process correctly.
Cause
System parameters or functions set incorrectly.
Solution
Reset the system and the welding/cutting parameters.
Cause
Faulty potentiometer/encoder for the adjustment
of the welding/cutting current.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sy-
stem repaired.
Cause
Mains voltage out of range
Solution
Connect the system correctly.
Read the paragraph "Connections ".
Cause
Input mains phase missing.
Solution
Connect the system correctly.
Read the paragraph "Connections ".
Cause
Faulty contactor.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sy-
stem repaired.
Cause
Faulty electronics.
Solution
Contact the nearest service centre to have the sy-
stem repaired.
Wire feeder fails
Cause
Faulty torch trigger button.
Solution
Replace the faulty component.
Contact the nearest service centre to have the sy-
stem repaired.
43

Publicité

loading