Speed control function
You can toggle the speed control (RPM
adjustment) ON/OFF and configure the rota-
tion at low speeds within the designated time.
1. Set the tool to setting configuration mode.
(See page 20.)
2. Press the B button three times.
The setting value will be displayed.
[Fig.27]
3. Press the
desired value.
Display
P0
P1
P2
P3
P4
4. Press the OK button to accept the new
setting.
[Fig.28]
[EYFLF]
Setting the undetect time
To set the time to undetect the function of
"snug point detection level" from the start
tightening, do as follows.
1. Set the tool to the configuration mode.
(See page 20.)
2. Press button A three times.
• The current set value is displayed, and
the main unit panel starts flashing.
Display: J0 flashing.
Battery capacity indicator: The upper
and lower bars flash.
[Fig.29]
3. Press
and
change the time.
Operation
4. Press the OK button to accept the new
setting.
and
buttons to set the
Function
Speed control ON
Speed control OFF
Low-speed rotation 0.2 sec.
Low-speed rotation 0.3 sec.
Low-speed rotation 0.4 sec.
buttons as required to
Display
Seconds
30
3
1
0.1
J0
OFF
[EYFLF]
Setting the impact speed
corresponding to the length of the
socket used
Due to the specifications of this product, this
item can be set, but the impact speed will not
be changed.
1. Set the tool to the configuration mode.
(See page 20.)
2. Press button D three times.
• The current set value is displayed, and
the main unit panel starts flashing.
Display: h0 flashing.
Battery capacity indicator: The upper
and lower bars flash.
[Fig.30]
3. Press
and
change the value.
Display
h0
h1
h2
4. Press the OK button to accept the new
setting.
[EYFLF]
Setting use interval
Use interval is set to prevent the screwdriver
from continuing its operation when the tool is
automatically stopped due to the implementa-
tion of the torque correction feature. This set-
ting is valid even when the switch is off.
1. Set the tool to the configuration mode.
(See page 20.)
2. Press button D twice.
• The current set value is displayed, and
the main unit panel starts flashing.
Display: U flashing.
Battery capacity indicator: The upper
and lower bars flash.
[Fig.31]
‒ 24 ‒
buttons as required to
Impact Speed Standard
Due to the specifications of
this product, this item can be
set, but the impact speed will
not be changed.