Display
EN
R0
R1
R2
4. Press the OK button to accept the new
setting.
[EYFLF]
Rundown error detecting function
The rundown error detecting function caus-
es a red indicator to flash if work ends more
quickly than a set time, for example due to
retightening of a previously tightened fastener
or binding of the screw's thread.
1. Set the tool to setting configuration mode.
(See page 20.)
2. Press the B button twice.
The rundown error detecting function set-
ting value will be displayed.
[Fig.21]
3. Press the
time as desired.
Buttons
4. Press the OK button to accept the select-
ed setting.
When the cross thread reduction function
is ON, the set time will be counted after
the tool operates in reverse for approxi-
mately 360°.
[EYFLF1R / EYFLF2R]
Radio signal range limitation
function on/off setting
1. Set the tool to configuration mode.
(See page 20.)
2. Press the C button.
• The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and
lower bars of the battery flash on and
off.
[Fig.23]
Function
OFF
360° reverse rotation
180° reverse rotation
and
buttons to change the
Display
Seconds
30
3
1
0.1
0
OFF
3. Press the C button twice.
• Radio signal range limitation function
ON/OFF setting value will be displayed.
[Fig.24]
4. Press the
signal range limitation function ON/OFF.
Radio signal
Display
range limitation
function mode
C0
OFF
C1
ON
5. Press the OK button to accept the new
setting.
NOTE:
• For more information about how to regis-
ter the tool and Assembly Qualifier, see
the Assembly Qualifier instruction man-
ual.
Factory settings
• Radio signal range limitation function
setting: C0 (OFF)
[EYFLF1R / EYFLF2R]
One-way and two-way
Communication function setting
1. Set the tool to configuration mode.
(See page 20.)
2. Press the C button four times.
• The control panel will begin flashing.
Display: The letter "q1" flashes on and
off.
[Fig.25]
3. Press the OK button to accept the new
setting.
Display
q0
One-way Communication
q1
Two-way Communication
‒ 22 ‒
and
buttons to set radio
Status
Tool is operational
in the absence of
communications
with the Assembly
Qualifier.
Tool is not operational
in the absence of
communications
with the Assembly
Qualifier.
Function