3. Press
and
as required to change the
time.
Operation
Display
4. Press the OK button to accept the new
setting.
• The control panel stops flashing and
lights up to display the torque clutch
settings.
NOTE:
Check the new value after you change the
settings.
[EYFLF]
Initializing all settings
Factory settings
• Torque clutch setting: "F" (torque control
function off)
• Interval setting: U or 0 (OFF)
• Snug point detection level → L1
• Cross thread reduction function → R0
• Rundown error detecting function → 0
• Tightening time reminder → 0
• Radio signal range limitation function →
C0
• Buzzer setting → b0
• LED light setting → d1
• Speed control setting → P0
• Undetect time setting → J0
• Impact speed setting corresponding to
the length of the socket used → h0
[EYFLF1R / EYFLF2R]
• One-way and two-way communication
function → q0
• This section explains how to revert all tool
settings to their default values at the time of
shipment from the factory.
Seconds
U9
3
U8
2.5
U7
2
U6
1.5
U5
1.2
U4
1
U3
0.7
U2
0.5
U1
0.3
U0
0.1
U
OFF
• The error display will be turned off.
1. Set the tool to the setting configuration
mode. (See page 20.)
2. Press the C button.
The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and
lower bars of the battery flash on and off.
[Fig.32]
3. Press the OK button to accept the select-
ed setting.
The control panel will stop flashing and
light up.
[EYFLF]
Checking Tool Settings
Confirm the set statuses of torque,
snug point determining level,
buzzer, and undetect time setting
Press button A.
The set statuses of torque, snug point deter-
mining level, buzzer, and power-off time
setting (without detection) are displayed in
sequence.
For example, when the torque is 30, the
snug point determining level is L1, the buzz-
er green indicator is lit and the buzz is heard,
and the undetect time is set to 1 second, the
display is as follows:
"30" → "L1"→ "b1" → "10"
[EYFLF]
Check the statuses of LED light and
fault detection during running, as
well as the setting of speed control
Press button B.
The set statuses of LED light, tightening time,
and speed control setting are displayed in
sequence.
For example, when the LED light mode is set
to d1, the tightening time is set to 20, and the
speed control is set to "ON", the display is as
follows:
"d1" → "20" → P0
[EYFLF]
Confirm the set statuses of main
unit ID, tilt tightening reduction,
repeat tightening prevention, and
impact speed setting corresponding
to length of socket used
‒ 25 ‒
EN