NOTE:
• Panasonic Assembly Qualifier Model
No.EYFR02 : One-way communication
only
Factory settings
• One-way and two-way communication
function setting: q0 (One-way commu-
nication)
[EYFLF1R / EYFLF2R]
Two-way Communication displays
• When the tool is in "Two-way Communica-
tion Stand by" mode, Tightening confirma-
tion lamp blinks in Orange to indicate.
[Fig.11]
• The control panel display shows the tool's
mode.
[Fig.26]
Display
- -
Tightening complete
CP
Operation Disabled Mode
[EYFLF]
Tightening time reminder
The tool is locked when it reaches the set
tightening time, and the main unit stops oper-
ation. This feature is convenient for regular
inspection of the tool performance.
1. Set the tool to setting configuration mode.
(See page 20.)
2. Press the C button twice.
The setting value will be displayed.
3. Press
and
change the time.
Operation
Display Tightening time
4. Press the OK button to accept the new
setting.
NOTE:
• When the remaining time prior to the
tightening time is less than 1 hour, the
display will alternate between the "set
value" and "-1".
Status
buttons as required to
99
99 hours
1
1 hour
0
OFF
If the current tightening time remains
unchanged and the inspection duration
is extended, the new set value must be
greater than the current one.
When it reaches the set time, the display
alternates between the set value and 0.
[EYFLF]
Buzzer setting
You can select from three buzzer modes.
1. Set the tool to setting configuration mode.
(See page 20.)
2. Press the A button twice.
The current setting value will be displayed.
3. Press the
desired value.
Display
b0
b1
Buzzer accompanying green indicator
b2
Buzzer accompanying red indicator
4. Press the OK button to accept the new
setting.
NOTE:
The tool ships with the buzzer mode set to
b0 by default.
[EYFLF]
LED light setting
You can select from two LED light modes.
1. Set the tool to setting configuration mode.
(See page 20.)
2. Press the B button once.
The current setting value will be displayed.
3. Press the
desired value.
Display
d1
Linked to LED light button
d2
Linked to trigger switch operation
4. Press the OK button to accept the new
setting.
NOTE:
The tool ships with the LED light mode set
to d1 by default.
‒ 23 ‒
and
buttons to set the
Function
No buzzer
and
buttons to set the
Function
EN