Manual Choke Start
If the battery is dead or not able to produce enough
current to power the push button choke, the choke itself
can be operated manually to help start the engine. To
manually choke and start the inverter, follow these steps:
1.
Loosen the screws and remove the maintenance
cover. (A)
2.
Locate the yellow manual choke lever. (B)
3.
Turn the choke lever to the "CHOKE" (right)
position. (B)
4.
Turn the fuel valve to the "ON" position.
5.
Turn the engine switch to the "ON" position.
6.
Pull the recoil rope until resistance is felt, then pull
rapidly.
7.
As the engine starts to roll over, move the choke lever
to the "RUN" (left) position.
for the 73001i-P only.
Manual Choke Start Cont'd.
NOTE
Keep choke lever in "Choke" (right) position for only
1 pull of the recoil starter. After first pull, move the
choke lever to the "Run" (left) position for up to the
next 3 pulls of the recoil starter. Too much choke
leads to spark plug fouling/engine flooding due to
the lack of incoming air. This will cause the engine
A
not to start.
Economy Control Switch
Using the Economy Control Switch will minimize fuel
consumption and noise when the generator is not
operating at full load. When the Economy Switch is off
then the generator runs at normal speed continuously.
B
WARNING
For periods of high electrical load or momentary
fluctuations, the Economy Control Switch should be
turned OFF.
B
OPERATION
EN
11