INSTALLATION
Placement
CAUTION
Before moving the unit into position, secure doors and
drawers closed and protect any finished flooring.
Use an appliance dolly to move the unit near the opening.
If the unit has been on its back or side, it must stand upright
for a minimum of 24 hours before connecting power.
Plug the power cord into the grounded outlet and roll the
unit into position. Verify the anti-tip bracket is properly
engaged.
Water Line
Approximately 3'
of
1
/
(.9 m)
the unit with a preassembled
under the unit. The water line fitting connection kit, provided
with the unit, contains a
1
/
4
connection to the household water line.
Purge the water line prior to final connection to the unit. This
will remove any debris that may be present in the tubing
from installing the new water line.
Place the sleeve and nut on the water line and fasten
to the connection at the end of the tubing. Do not over
tighten. Check all water line fittings for leaks. Verify the
drain pan can be installed and removed without water line
interference.
If a reverse osmosis system used, it is
IMPORTANT NOTE:
recommended that the water filtration system be bypassed
by removing the filter.
IMPORTANT NOTE:
Water lines can not be exposed to
freezing temperatures.
|
8
Sub-Zero Customer Care 800.222.7820
All manuals and user guides at all-guides.com
" plastic tubing is connected to
4
1
/
" compression connection
4
" compression union fitting for
Alignment
LEVELING
Once the unit is in position, turn the front leveling legs
clockwise to adjust the height. The rear height adjustment
can be made from the front of the roller base. Using a
socket, turn the
3
/
" hex bolt clockwise to raise the unit or
8
counterclockwise to lower. Use the lowest torque setting
when using a power drill. Do not turn the rear leveling legs
by hand. Refer to the illustration below.
When the unit is properly leveled, door and drawer adjust-
ments are less likely to be necessary.
Level the unit to the floor, not sur-
IMPORTANT NOTE:
rounding cabinetry. This could affect the operation of the
unit, such as door closing.
WARNING
To reduce the possibility of the unit tipping forward, the
front leveling legs must be in contact with the floor.
REAR
ADJUSTMENT
FRONT
LEVELING LEG
Leveling.
3
/
"