Installation of the drain hose
•
3
Remove the drainage tray and connect the
corrugated hose, supplied with the machine, to
the drainage tray outlet (see figure), before
finally connecting the other end to the general
drainage system of the establishment.
Drainage tray outlet
i
It is important that the drain hose is completely
straight and does not hang loose to enable
good drainage.
Operation (Automatic machines)
•
Turn the main switch clockwise to start the machine.
5
•
After switching on, the electronic control unit detects
that there is no water level in the boiler, activating
the solenoid valve and the pump, which both remain
active until the level gauge detects the correct water
level. The boiler heating element will then be
activated, heating the whole system.
If the control unit does not detect water level in
i
the boiler for a certain duration, all the LEDs of
the programmable buttons will flash continuously.
hostelearte.com
The alarm will disappear with the turning off and
subsequent turning on of the machine. (see section
6, page 26).
Off
On
Electrical connection
•
4
Connect the machine to a suitable connection,
in line with current electrical regulations.
•
Connect the machine according to the mains
voltage of the establishment as indicated on
the label attached to the installation cable, see
figure a).
i
You should not use any type of extension cords
or power strips to connect the machine to the
power supply.
The power connection cable should never be
rolled up, but instead should be fully extended to
prevent possible overheating.
Operation (Semi-automatic machines)
•
Turn the main switch clockwise to select position 2,
5
without heater (heater disabled
•
At the beginning the electronic control unit detects
that there is no water level in the boiler, activating
the solenoid valve and pump, which both remain
active until the level gauge detects the correct water
level. Then urn the main switch counterclockwise to
position 1 (heater enabled).
Heater disabled
This model don't have water level alarm into
i
boiler. So, you will have to make sure the boiler
have a correct level of water before heater
enable.
22
24
Electrical
Conection label
Figure a)
).
Off
Heater enabled