To Set Turbo Cell Type
Before operation, the AquaRite must be configured for the chlorinator cell that will be used. Your model
AquaRite has been packaged with a corresponding Turbo cell. Refer to the following information and
steps below to set the Turbo cell type.
"t-3" = for all W3AQR3 if using a T-CELL-3, GLX-CELL-3-W
"t-9
= for all W3AQR9 if using a T-CELL-9, GLX-CELL-9-W
"t-15" = for all W3AQR15 if using a T-CELL-15, GLX-CELL-15-W
"t-5" = if using a GLX-CELL-5, GLX-CELL-5-W
1. Slide the Main Switch from "Off" to the "Auto" position.
2. Push the Diagnostic button repeatedly until "t-3", "t-5", "t-9" or "t-15" appears on the display
("t-15" is the factory default). If the desired cell type is displayed skip to step 4.
3. To change to a different cell type, slide the Main Switch from "Auto" to "Super Chlorinate" and
back to "Auto". Repeat this process until the desired cell type is displayed.
4. Push the Diagnostic button to exit.
Desired Output %" adjustment knob
The "Desired Output %" adjustment knob is located in the lower center of the AquaRite control panel.
This setting is used to control the amount of chlorine the AquaRite generates. Raise this setting to
increase chlorine level and lower it to decrease chlorine level. Note: The "Desired Output %" adjust-
ment will not function when the AquaRite is being controlled by a remote pool automation control.
Salt Display
Refer to the Water Chemistry section for recommended salt levels as well as how to add/remove salt.
The Salt Display shows the average salt level of the pool water. The factory default display is in English
units (ppm). If Metric units (grams per liter) are preferred, follow the procedure under Temperature
Display. When the AquaRite is displaying grams per liter, the readout will show a decimal point. (ex.
3.2 g/l = 3200ppm).
Temperature Display
The Temperature Display shows the current temperature of the pool water. The factory default display
is in ºF. Both the Temperature Display and the Salt Display can be programmed to display in Metric
units. To display temperature in ºC and salt level in g/l, perform the following steps:
1. Slide the Main Switch from "Off" to the "Auto" position.
2. Push the Diagnostic button repeatedly until "ºF" appears on the display.
3. Slide the Main Switch from "Auto" to "Super Chlorinate" and back to "Auto".
4. Push the Diagnostic button to exit.
Instant Salinity
The Instant Salinity display is the measured salt level of the pool water at that moment. If salt has
recently been added, the Instant Salinity may show the change while the Salt Display (average salt
level) may take some time before the changes can be seen. Under these circumstances, you may