Input Power For stand alone operation:
W3AQR15, W3AQR9, W3AQR3 - Refer to the wiring label on the AquaRite as well as the diagram
below to determine correct wiring connections. The AquaRite is shipped from the factory with the
configuration jumpers in 240VAC position. If using 120VAC, move the jumpers as shown below. For
Canadian models, the AquaRite shall be connected to a circuit protected by a class A ground fault
interrupter. Be sure to connect the ground wire to the green ground screw terminal located on the
bottom of the enclosure.
TYPICAL 240 VAC WIRING
SUBPANEL
GROUND
Bonding: Two bonding lugs are provided on the exterior enclosure, one to be used for US installations
and both for Canadian. To reduce the risk of electric shock, connect the local common bonding grid
in the area of the swimming pool, spa, or hot tub to these terminals with an insulated or bare copper
conductor not smaller than 8 AWG US / 6 AWG Canada.
13
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
GFCB
PUMP
Flow Switch
Connector
AQUA
RITE
GND
PCB
BONDING
LUG
BONDING
LOOP
Cutout for
cell cable
Bonding lugs to
pool bonding system
120 VAC
AQUA
RITE
GND
PCB
BONDING
LUG
IMPORTANT:
MOVE JUMPERS
TO POSITIONS SHOWN