IMPORTANT SAFETY INSTRUCTIONS
When using this electrical equipment, basic safety precautions should always be followed, includ-
ing the following:
READ AND FOLLOW ALL INSTRUCTIONS
•
•
Disconnect all AC power during installation.
WARNING - To reduce the risk of injury, do not permit children to use this product unless they
•
are closely supervised at all times.
•
A green colored terminal marked "Earth Ground" is located inside the wiring compartment.
To reduce the risk of electric shock, this terminal must be connected to the grounding means
provided in the electric supply service panel with a continuous copper wire equivalent in size
to the circuit conductors supplying the equipment.
WARNING - Risk of Electric Shock. Connect only to a grounding type receptacle protected
•
by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify
that the receptacle is protected by a GFCI.
•
Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and
other equipment.
•
WARNING - To reduce the risk of electric shock, replace damaged cord immediately.
WARNING - To reduce the risk of electric shock, do not use extension cord to connect unit to
•
electric supply; provide a properly located outlet.
•
Two bonding lugs are provided on the exterior enclosure, one to be used for US installations
and both for Canadian. To reduce the risk of electric shock, connect the local common bond-
ing grid in the area of the swimming pool, spa, or hot tub to these terminals with an insulated
or bare copper conductor not smaller than 8 AWG US / 6 AWG Canada.
•
All field installed metal components such as rails, ladders, drains, or other similar hardware
within 3 meters of the pool, spa or hot tub shall be bonded to the equipment grounding bus
with copper conductors not smaller than 8 AWG US / 6 AWG Canada.
•
Hayward salt systems are designed, tested and sold as systems and are certified by several
agencies around the globe --- with each component of the systems meeting all required
certifications and attendant legal requirements. The use of an untested, uncertified generic
cells (or generic circuit boards) with Genuine Hayward salt chlorination products could lead to
premature product failure.
•
Pursuant to the terms and conditions of any applicable Warranty, the use of a non-genuine
Hayward replacement salt chlorination cell on any Hayward automation or chlorination product
will void any Warranty.
1
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
SAVE THESE INSTRUCTIONS