6.2 With the hidden key of a transmitter already learnt.
Always when the automation is still, press with the help of a clip the hidden key of a transmitter already learnt. The beginning of the learning proce-
dure is indicated by some long beeps at each second. Once entered into the learning stage follow the procedure mentioned at point 6.1.1 in case you
need to learn a two buttons transmitter or follow the procedure at point 6.1.2 in case you wish to learn a three buttons transmitter.
7. Selectable functions through dip-switch
It is important to change the configuration of the dip-switch only when the unit is
turned off!!! Turn off the power supply during the change of configuration.
Default settings
The control board is supplied with the dip-switches set as indicated in the Pict. 1. In the table are sum up the functions that can be selected through
these dip-switches.
Fig.1: factory setting
of the dip
7.1 Operating on opening/closing
This function enables to select the method of opening / closing of the automation.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
The functioning mode with "pulse functioning" activated can be selected by dip 4.
6-1622605
rev.0
07/05/2013
All manuals and user guides at all-guides.com
dip
1
Function on opening
2
Function on closing
3
4
Pulse functioning
5
6
Safety edge test
The automation works under dead man mode on opening.
The automation works under pulse mode on opening.
The automation works under dead man mode on closing.
The automation works under pulse mode on closing.
ITA
Function
Working time
Photocells test
Dip-switch function table
ENG
FRA
ESP
DEU
POR
Dip OFF
Dead man
Pulse on opening
Dead man
Pulse on closing
Programmable
Open — close
Step by step ( GO function )
Desabled
Desabled
Dip ON
Infinite
Enabled
Enabled
5 / 8