7.2 Working time
The setting of this dip enables to choose between a working time manually set through a trimmer or an infinite working time.
ON
An infinite working time is set, the output remains activated till the reception of a stop or an opposite motion impulse.
OFF
ON
The working time is manually set through the "Run Timer" trimmer adjustment (see paragraph 6).
OFF
7.3 Pulse operation
The setting of this dip configures the operating mode, when the dip 1 and the dip 2 are set on ON (pulse operation).
ON
The "Go functioning" is activated. The automation works under "step by step" mode with one button. The UP button
OFF
makes the sequence open -stop-close. While the stop can be obtained pressing the button DOWN (or STOP in case of
a 3 buttons transmitter).
ON
The open– close function with two buttons is activated . Pressing the button UP the automation closes a further closing
impulse ( or stop) stops the automation, pressing the button DOWN the automation starts closing.
OFF
The "GO" function is automatically excluded with the dip 1 and/or the dip 2 set on ON.
7.4 Photocells test
This control unit is equipped with a system that enables to perform a control on the functioning of the photocells before each closing movement of the
motor. In this way we have the possibility to increase the safety of the system in case of damage of the photo device ( for example output relay stuck)
or an undesired short-circuit on the photocells input. This checking is performed after that the control unit has received a closing impulse but before
giving power to the motor.
ON
Photocell test activated
OFF
ON
Photocell test deactivated
OFF
Note: the test of the photocell, if activated , causes a delay of the motor operation of about one second from the moment of the impulse re-
ception.
7.5 Edge test
This control unit is equipped with a system that enables to execute a control on the functioning of the safety edge before each closing operation of the
motor. There is the possibility to increase the safety of the system in case of damage of the device or of an undesired short-circuit on the safety edge
input. This checking is performed after that the control unit has received a closing impulse but before powering the motor.
ON
Safety edge test activated
OFF
ON
Safety edge test deactivated
OFF
Note: the safety edge test, if activated, causes a delay of the motor operation of around one second from the moment of the impulse recep-
tion.
6-1622605