11
Technical data
11.1
Electrical data
Power supply (switching power supply unit)
Electrical safety
Max. power absorption AC 110 to 240 V
AC / DC 20 to 30 V
Data backup
Electrical connection
Electromagnetic compatibility (EMC):
Emitted interference
Immunity to interference
11.2
Housing
Housing type
Materials
Dimensions
Ambient temperature during operation
Ambient temperature
Climate resistance
Operating position
Safety class
Closed housing
Open housing
Cable entries
Scope of supply
Standard configuration
Full equipment set
(see accessories)
Weight without wall bracket (fully loaded)
Weight of wall bracket
Installation torques of the cable glands
AC 110 to 240 V + 10 / -15%;
48 to 63 Hz or
AC / DC 20 to 30 V; 48 to 63 Hz
According to DIN EN 61010, part 1 Overvoltage Category
III, pollution degree 2
53.7 VA
26.2 VA
Flash memory
Spring terminals and screw terminals
Information on cable cross-sections
see operating instructions 417102269,
chapter 'Conductor cross-sections of base and power
supply unit' or
chapter 'Option board conductor cross-sections' .
DIN EN 61326-1
Class A
Industry requirement
Surface-mounting housing made of plastic (ABS)
Terminal compartment cover screws: Stainless steel 1.4567
Mounting plate: Stainless steel 1.4301
301.5 mm × 283.2 mm × 120.5 mm
-5 to +50°C for device version with power supply AC 110 to
240 V
-5 to +45 °C for version with power supply AC/DC 20 to 30 V
-30 to +70 °C
Relative humidity < 92% annual average without
condensation
Any, taking into account the viewing angle of the screen
according to DIN EN 60529
IP67
IP20
Cable glands:
6× M12 × 1.5
3× M16 × 1.5
Cable glands:
9× M12 × 1.5
2× M16 × 1.5 2× M20 × 1.5
3390 g
790 g
0.7 Nm for M12 × 1.5
2 Nm for M16 × 1.5
2.7 Nm for M20 × 1.5
61
Technical data
417102279 Rev. 4-07.2023