Part 2
INSTALLATION REQUIREMENTS
INSTALLATION DRAWINGS
3
The first step of the installation is to measure the current cutout dimensions and compare them to the cutout
dimensions shown below. Little or no cabinet work may be necessary.
IMPORTANT NOTE
• The cabinet base platform must be able to support 325lbs (147kg). If the cabinet does not have a solid bottom,
two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven.
Make sure the base is level and the front of the cabinet is square. If the cabinet base is not level, the oven racks
will tend to slide out when opening the door.
• If marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood
shims under the runners and front trim until the marks or opening are covered.
• If the cabinet does not have a front frame and the sides are less than 3/4" (1.9 cm) thick, shim both sides
equally to establish the cutout width.
• The junction box must be flush with the rear wall of the cabinet as shown below.
• Allow at least a 23" clearance for the door depth when it is open.
• Kitchen cabinets in contact with the oven must be heat resistant up to 194°F (90°C), and fronts of nearby units
up to at least 158°F (70°C).
• Do not remove the gliding racks from the base packing. Gliding racks are attached separately to the top and
bottom of the oven.
A
B
-
Dimensions
A
Height
B
Width
C
Depth
D
Height (standard installation)
E
Height (power cord)
F
Length (power cord)
G
Width (back)
H
Width (standard installation)
I
Cabinet width
J
Overlap of oven
K
Cutout width
L
Depth of open door
M
Cutout height
N
Cutout depth
O
Cutout location from floor
P
Height of conduit opening from floor of cutout
Q
Distance of conduit opening from side of cabinet
(SKSDV3002S, FOR 30" DOUBLE BUILT-IN OVEN)
F
E
D
C
a Conduit opening
b Circuit breaker
H
G
J
L
Double Oven
52 1/16" (1323 mm)
29 3/4" (755 mm)
23 3/8" (593 mm)
51 9/16" (1310 mm)
50 5/16" (1277.2 mm)
60" (1524 mm)
27 3/8" (695.3 mm)
28 3/7" (722 mm)
30" (762 mm)
1" (25.4 mm)
28 1/2" Min. (723.9 mm), 28 5/8" Max. (727 mm)
23" (584.2 mm)
51 13/16" Min. (1316 mm), 51 15/16" Max. (1319.2 mm)
24" Min. (610 mm)
12" (304.8 mm)
47" (1193.8 mm)
5" (127 mm)
- 8 -
Q
I
K
P
M
N
O