Part 3
ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTION REQUIREMENTS
1
The third step of the installation is to follow the electrical connection requirements below.
Ensure that dedicated circuit protection is prepared as recommended and that the oven is grounded properly.
IMPORTANT NOTE
Be sure the wall oven is installed and grounded properly by a qualified installer or service technician.
• This wall oven must be electrically grounded in accordance with local codes or, in their absence, with the
National Electrical Code ANSI/NFPA No.70- latest edition in United States, or with CSA Standard C22.1-1982 and
C22.2 No.01982 (or latest edition), Canadian Electrical Code, Part1, and all local codes and ordinances.
• This wall oven must be supplied with the proper voltage and frequency, and connected to an individual,
properly grounded branch circuit, protected by a circuit breaker or fuse. To know the circuit breaker or fuse
required by this model, see the rating plate to find the wattage consumption and refer to the table below to get
the circuit breaker or fuse amperage.
[Appliance rating Watts 240 V]
Category
Single wall oven
Double wall oven
Combi wall oven
[Appliance rating Watts 208 V]
Category
Single wall oven
Double wall oven
Combi wall oven
IMPORTANT NOTE
• Do Not ground to a gas pipe.
• Do Not have a fuse in the neutral or grounding circuit.
• A U.L.-listed conduit connector must be provided at the junction box.
WARNING
• New branch-circuit installations
(1996 NEC), mobile homes,
recreational vehicles, or
installations where local codes
prohibit grounding through the
neutral conductor require 4-wire
branch-circuit connection.
Power Consumption
6100 W
10200 W
7800 W
Power Consumption
4600 W
7700 W
6200 W
- 13 -
Protection circuit
recommended
40 A
50 A
40 A
Protection circuit
recommended
30 A
50 A
40 A
WARNING
• Improper connection of aluminum
house wiring to copper leads can
result in an electrical hazard or
fire. Use only connectors designed
for joining copper to aluminum
and follow the manufacturer's
recommended procedure closely.
Wire gauge
recommended
12 AWG
8 AWG
10 AWG
Wire gauge
recommended
12 AWG
8 AWG
10 AWG