Part 2
INSTALLATION REQUIREMENTS
Cutout Dimensions (Flush)
N
C
D
E
G
F
Cleat
(Spacer)
• The provided cover brackets are only used for flush cabinet installations.
• Remove one screw from the left and right sides as shown. These screw holes will be used to mount the cover
brackets. Install the cover brackets on the sides of the oven with the provided self-tapping screws.
M
L
K
J
I
H
a Conduit opening
b Circuit breaker
Cover Bracket
4X22
Tapping Screw
- 5 -
-
Dimensions
C
Cutout width
D
Cleat (spacer) inset from front
of cabinet
E
Cleat (spacer) width
F
Cleat (spacer) depth
G
Depth of open door
H
Bottom of cutout from floor
I
Cutout depth
J
Cleat (spacer) height
K
Cutout height
L
Height of conduit opening from
floor of cutout
M
Distance of conduit opening
from side of cabinet
N
Bottom of bottom decorative
trim to vent opening
Single Oven
30" (762 mm)
1 3/8" (34.8mm)
3/16" (5 mm)
1" (25.4 mm)
23" (584.2 mm)
31" (787.4mm)
25" (635.0 mm)
29 5/8" (752.4 mm)
28 9/16" (726 mm)
23 1/2" (596.9 mm)
5" (127mm)
3/4" (19 mm)