Télécharger Imprimer la page

Grohe EUROSMART COSMOPOLITAN E 36 334 Instructions D'installation page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
Performing continuous operation for thermal disinfection
1.
Have hot water provided on site or turn the thermostatic
cartridge to the hot water end stop.
2. Hold finger against the lower area of the sensor system,
see Fig. [9].
Indicator lamp signals:
██████████████████████ ██ ██ ██ ██ ██ ██ ██ ▌▌▌▌▌
3.
Remove finger from the sensor system while
is displayed.
Indicator lamp signals:
██ ██ ██ ██
Take hands out of the detection zone of the
sensor system.
Thermal disinfection starts once the remaining capacity has
been signalled.
If an object is detected during thermal disinfection, the water
stops flowing immediately and the fitting is closed (indicator
lamp starts to flash).
Closure of the fitting ends automatically after 3 minutes or
can be prematurely terminated (see Terminating cleaning
mode).
Making settings
Setting mode
Setting mode has the following functions:
- Querying and changing the programme
- Checking the detection zone
The indicator lamp in the sensor system illuminates in setting
mode when the detection zone of the fitting is reached by an
approaching user.
Activating setting mode
Disconnect the power supply to the electronics and reconnect
after 10 s, see Figs. [10] and [11].
• Setting mode is automatically terminated after 3 minutes.
Setting the programme
1.
Activate setting mode.
2. Hold finger against the lower area of the sensor system,
see Fig. [9].
Indicator lamp signals:
▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌▌___
3.
Remove finger from the sensor system while
displayed.
Programme selection mode is active for 60 s.
4. Hold finger against the lower area of the sensor system.
The programmes are displayed by groups of flashing
signals via the indicator lamp. Display starts with
the programme that is currently set.
Programme 1
██
Programme 2
██ ██
Programme 3
██ ██ ██
Programme 4
██ ██ ██ ██
Programme 5
██ ██ ██ ██ ██
Programme 6
██ ██ ██ ██ ██ ██
Programme 7
██ ██ ██ ██ ██ ██ ██
5
All manuals and user guides at all-guides.com
5. Remove finger from the sensor system after the desired
The programme is adopted as the new setting. The
corresponding flashing signals are displayed again.
The setting can be readjusted within the next 6 s if necessary
Setting mode is automatically terminated after 3 minutes.
▌▌▌▌
Maintenance
• Shut off water supply.
• Disconnect voltage supply.
• Inspect and clean all components and replace if necessary.
I. Switched-mode power supply, see fold-out page II,
Figs. [10] and [12].
Assemble in reverse order.
II. Solenoid valve, see fold-out pages II and III, Figs. [10]
and [13].
Assemble in reverse order.
III. Remove and clean mousseur (13 951), see fold-out
page I.
Assemble in reverse order.
IV. Wall plate with electronics, see fold-out pages II and III,
Figs. [10], [14] and [15].
Assemble in reverse order.
Thermostatic cartridge
Only in conjunction with wall-mounting box 36 336.
Disassamble plate, see fold-out page II, Fig. [10].
Disassamble thermostat, see fold-out page III, Figs. [16] and
[17].
I. Non-return valve (A) / Filters (B), see Fig. [18].
Remove union nipple (C) by turning clockwise (left-hand
thread).
Assemble in reverse order.
II. Thermostatic cartridge, see Fig. [19].
Assemble in reverse order.
Replacement parts
see fold-out page I (* = special accessories)
is
Care
____
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
sequence of flashing signals.
(see 4.)

Publicité

loading

Ce manuel est également adapté pour:

Eurosmart cosmopolitan e 36 335