GB
Safety notes
• Installation is only possible in frost-free rooms.
• The switched-mode power supply is only suitable for
indoor use.
• In the case of damage to the external connection cable of the
power supply unit, it must be replaced by the manufacturer
or the manufacturer's customer service department or an
equally qualified person, in order to prevent a hazard.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Technical data
• Flow rate at 0.3 MPa flow pressure:
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
• Automatic safety shut-off:
(6 - 420 s adjustable)
• Run-on time (0 - 11 s adjustable):
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (15 - 35cm adjustable):
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
General functions
• Thermal disinfection:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system, see the programme table on page 6.
Special accessories
Further settings and special functions are available via the
infrared remote control (prod. no. 36 206).
Approval and conformity
This product conforms to the requirements of the
relevant EU directives.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
All manuals and user guides at all-guides.com
Installation
Plaster and tile the wall, excluding the area of the structural
shell protection.
Cut off inspection chamber flush with tiles, see fold-out page II,
Fig. [1].
Flush pipes thoroughly before and after installation
(observe EN 806).
Connect fitting, see Figs. [2] to [6].
Open hot and cold water supply and check that
connections are watertight.
Temperature adjustment, see Fig. [7]
Only in conjunction with wall-mounting box 36 336.
approx. 9 l/min
The thermostatic cartridge is set to 38 °C at the factory.
The temperature is regulated by turning adjusting screw.
2.4 W
60 s
Installing the plate, see Fig. [8].
1 s
Operation
25cm
The infrared electronics emit invisible, pulsed light.
The sensor system is adjusted so that water flow is initiated
when the hands approach the vicinity of the spout. When the
hands are withdrawn from the vicinity of the spout, water flow
A
is stopped after 1 s.
2
The range of the sensor system is dependent upon the
2500 V
reflective properties of the detected object.
100 °C
Automatic safety shut-off
After 60 s of continuous detection of an object, the infrared
electronics automatically stop the water flow.
Activating cleaning mode
activatable
• Only possible when temporary shutoff is activated
1. Hold finger against the lower area of the sensor system,
activatable
deactivated
3.5 min
█████████████████████ ██ ██ ██ ██ ██
2.
Remove finger from the sensor system while
Cleaning mode is active for 3 minutes. The indicator lamp
Terminating cleaning mode prematurely
1. Hold finger against the lower area of the sensor system,
█████████████████████____
2.
Remove finger from the sensor system while
see Fig. [9].
Indicator lamp signals:
██ ██ ██
is displayed.
flashes during this time.
see Fig. [9].
Indicator lamp signals:
____
displayed.
Cleaning mode is terminated.
is