Storage
1. Thoroughly clean the device (see section "Cleaning").
2. Let all parts dry completely.
3. Then store the device and its accessories in a dry and frost-free place (≥ +5 °C) without direct
sunlight.
Troubleshooting
Fault description
Charger blinks red.
The status indicator
5
The device cannot reach all places
in the pool.
The device does not completely
move up the wall.
The device does not sink.
The device rises to the surface.
Cause
Low rechargeable battery voltage or
faulty rechargeable battery.
blinks red.
Device is out of the water.
The water circuit of the pool is
switched on.
The device becomes stuck on the
drain grate.
The filter is clogged.
Algae grows on the walls.
The water temperature is too high or
too low.
The tires or the cleaning roller are/is
worn.
The device is too light and topples.
The pH value and the chlorine
quantity are not properly set.
There is air in the device.
The salt content is too high and the
device has more buoyancy.
The device climbs too high or there
is air trapped in the device.
The salt content is too high and the
device has more buoyancy.
Remedy
Contact customer service.
Place the device in the water or
switch it off if you are not going to
use it at present.
Switch off the filter system of the
pool.
Switch off the filter system of the
pool.
Clean the filter.
Manually pre-clean the pool walls.
Investigate and remedy the cause of
algae growth (e.g., pH value). Use
the pool cleaner more frequently.
Operate the device at water
operating temperature (see section
"Technical data").
Check the tires and the cleaning
roller for wear and replace them if
necessary.
Switch off the device and let all the
air escape.
Adjust the pH value and the chlorine
value to the correct value (see
section "Technical data").
Switch off the device and let all the
air escape.
Set the correct salt content. See
section "Technical data".
Switch off the device and let all the
air escape.
Set the correct salt content. See
section "Technical data".