● If you swallow the battery liquid, rinse your mouth and seek
medical attention as soon as possible. The chemical substances
in the battery may burn or cause other health hazards.
Safety Protections
1. Water-full safety alarm and shut – off protection function
When the water volume exceeds its alarm level in chassis,
warning sounds automatically and water-full icon will light in
display, you need to drain the water and re-start the unit. (For
more information about how to drain, refer to the "Drainage
Instruction" please). If the unit is not shut down manually, the unit
will recover to the original operating status automatically once the
water is fully drained. Or connect the power to re-start the unit
again.
2. Anti-frozen protection function (Optional)
Under COOLING mode, when the compressor continuously runs
over 10 minutes, if tube temperature is ≤2 °C /36 °F for 20
seconds, the anti-frozen protection function will be on, E4 will be
shown on LED display, compressor and water wheel motor will
stop working, but upper fan remains running; If tube temperature
≥8 °C /46 °F, the unit will stop anti-frozen protection and recover
to the original working condition. Compressor will re-start working
with 3 minutes delay for protection.
3. Delay protection function of compressor
This unit offers restart protection to compressor. Except that the
26
compressor may start immediately when the unit is energized first
time, there is 3-minute delay re-start protection after compressor
is shut down.
4. Coil and room temperature sensor failure:
1) Detect sensor failure at the beginning of power-on or power-on
state.
2) When a sensor failure is detected at the beginning of
power-on, it will immediately enter the failure state. If it returns to
normal at this time, it will enter the standby state;
AIR CONDITIONER USE
IMPORTANT: If the air conditioner has been tilted on its side, wait
24 hours before turning on the air conditioner to allow the oil to
return to the compressor. This will prevent the air conditioner from
failing prematurely.
Hold handles on side panels to move the unit in upright position.
NOTE:
● Do not hold the louver.