Control Box 3S io
CONNECTINg AddITIONAL dEvICES
general wiring diagram
230 V
500 W max.
... ...
230 V
50 Hz
230Vac
Lamp
Aux
L
N
3
4
5
6
7
1
2
1.5 mm²
0.75 mm²
Terminals
Terminal indication
1
L
2
N
3
4
5
N
6
L
7
Contact
8
Shared
9
0 V
10
9 V - 24 V
11
+
12
-
13
End limit
14
+
15
-
16
End limit
17
24 V - 15 W
18
0 V
19
24 V
20
0 V
21
24 V
22
0 V
23
Shared
24
Contact
25
+
26
-
27
Shared
28
Contact
29
Contact
30
Contact
31
Shared
32
Contact
33
Conductor
34
Braid
Copyright © 2015 Somfy SAS. All rights reserved
M1
M2
Batt.
M1
M2
-
+
M
M
+
-
+
-
FC
FC
8
9
1 0
1 1
1 2
1 3
1 4
1 5
1 6
1.5 mm²
1.5 mm²
0.75 mm²
Connection
230 V power supply
Earth
230 V lighting output
Auxiliary contact output
9 V / 24 V low voltage power supply input
Motor 1
Ixengo only
Motor 2
Ixengo only
24 V - 15 W orange light output
24 V accessories power supply
Safety device power supply
Safety input 1 - Cells
24 V lock or 12 V lock output
Safety input 2 - programmable
Safety test output
COMPLETE/OPENING control input
PEDESTRIAN/CLOSING control input
Aerial
15 W
TX
RX
24 Vdc
sec./Cell
Flash
24V dc
24V Cell
Lock
1 9
2 0
2 1
2 2
2 3
2 4
17
18
2 5
2 6
0.75 mm²
* terminals reserved for wiring for Ixengo motor end limits.
Comments
Max. power 500 W
Protected by 5A time-delay fuse
Dry contact for 24V, 2A max, Safety Extra Low Voltage (SELV)
At 9 V, degraded operation
At 24 V, normal operation
1.2 A max for all accessories on all outputs
Permanent if autotest not selected, controlled if autotest selected
Used to connect RX receiver cell
BUS compatible (see parameter table)
Programmable (parameter P17)
COMPLETE/OPENING cycle programmable
PEDESTRIAN/CLOSING cycle programmable
Do not change the position of the aerial.
Sec. Prog Test
Ant.
Sec.
33
34
2 7
2 8
2 9
3 0
3 1
3 2
8