Control Box 3S io
values
Code description
(bold = default)
p23 M1/M2 shift
1: minimum shift
when closing
at
10: maximum shift
Adjusted at the end of auto-
programming
p24 M1/M2 shift
1: minimum shift
when opening
at
10: maximum shift
Adjusted at the end of auto-
programming
p25 M1 closing torque
limitation
p26 M1 opening torque
limitation
p27 M1 closing slowdown
torque limitation
p28 M1 opening
1: minimum torque
slowdown torque
at
limitation
10 (Axovia) or 20 (Ixengo): maximum
torque
p29 M2 closing torque
Adjusted at the end of auto-
limitation
programming
p30 M2 opening torque
limitation
p31 M2 closing slowdown
torque limitation
p32 M2 opening
slowdown torque
limitation
p37 Wired control inputs 0: complete cycle mode -
pedestrian cycle
1: opening mode - closing
p39 Limit position
0: no time delay
maintaining time
1: with time delay
delay
p40 Coupling speed when
1: slowest speed
closing
at
4: fastest speed
default value: 2
p41 Coupling speed when
1: slowest speed
opening
at
4: fastest speed
default value: 2
Copyright © 2015 Somfy SAS. All rights reserved
Setting
Comments
completed
1: Minimum shift ensuring the leaves do not cross.
Disabled if hinged gate with 1 "covering" leaf.
10: maximum shift corresponding to the complete movement of one leaf then the other
IIf this parameter is modified, the installer must check that the limitation of forces complies
with appendix A of the standard EN12 453 or install a safety edge.
If the torque is too low, there may be erratic obstacle detection.
If the torque is too high, the installation may not comply with the standard.
0: terminal 30 input = complete cycle, terminal 32 input = pedestrian cycle
1: terminal 30 input = opening only, terminal 32 input = closing only
This parameter is only available on Control Box 3S Ixengo io models.
If this parameter is modified, the installer must check that the limitation of forces complies
with appendix A of the standard EN12 453 or install a safety edge.
14