CONTROL BOX 3S io
4.2. Memorising the Keygo io remote controls for
operation in complete opening - Fig. 6
To memorise Keytis io bidirectional remote controls, see "Memorising
Keytis io remote controls".
If this procedure is carried out using a channel which has already been
memorised, this channel will be cleared.
1) Press and hold the "PROG" button (2 s).
The screen displays "F0".
2) Press the outer le and right buttons on the remote control together.
The remote control indicator light flashes.
3) Press the button of the remote control that will open the gate fully.
The screen displays "Add".
4.3. Auto-programming
Auto-programming enables the travel, motor torques and gate leaf closing
shi to be adjusted.
4.3.1. Starting auto-programming - Fig. 7
The gate leaves must be in the intermediate position.
1) Press and hold the "SET" button (2 s).
release the button when the screen displays "H1".
To install an Ixengo L 24V, consult the motor installation manual to
adjust the motor end limits before moving on to stage 2).
2) Press "OK" to start auto-programming.
The gate performs two complete opening and closing cycles.
If auto-programming is correct, the display indicates "C1".
If auto-programming has not completed correctly, the display indicates
"H0".
Auto-programming mode is accessible at any time including when the
auto-programming cycle has already been completed and the display
indicates "C1".
Auto-programming can be interrupted by:
• activating a safety input (photoelectric cells, etc.)
• the appearance of a technical fault (thermal protection, etc.)
• pressing a control button (control box interface, memorised remote
control, wired control point, etc.).
In case of interruption, the display indicates "H0" and the control box re-
turns to "Awaiting setting" mode.
In "Awaiting setting" mode, the radio controls operate and the gate moves
very slowly. This mode must only be used during installation. Auto-pro-
gramming must be successfully performed before the gate can be used
normally.
During auto-programming, if the gate is stationary, pressing "SET" will exit
auto-programming mode.
Attention
Axovia 200, P>100kg : P19=5
Warning
At the end of installation, it is essential to check that the obstacle
detection complies with appendix A of standard EN 12 453.
5. OPERATING TEST
5.1. Using the remote controls - Fig. 8
Default sequential operating mode (P01=0)
5.2. Obstacle detection operation
Obstacle detection when opening = stop + partial reversal.
Obstacle detection when closing = stop + complete reopening.
Copyright
©
2017 SOMFY ACTIVITES SA. All rights reserved.
5.3. Operation of the photoelectric cells
With the photoelectric cells connected to the dry contact/Cell (terminals
23-24) and Cell safety input parameter P07 = 1.
• Cells obscured with gate open = the gate cannot be moved until the
operating mode changes to deadman operation (a er 3 minutes).
• Cells obscured when opening = the state of the cells is not taken into
account and the gate continues to move.
• Cells obscured when closing = the gate stops and reopens fully.
5.4. Anti-intrusion mode, wind resistance
Only on Control Box 3S Axovia io models.
Maintains the gate in the closed or open position by reinjecting current in
case of attempted intrusion or strong wind.
5.5. Specific operation
See the user booklet.
5.6. User training
All users must be trained on how to safely use this motorised gate (stand-
ard use and unlocking principle) and on the mandatory periodic checks.
6. CONNECTING ADDITIONAL DEVICES
6.1. General wiring diagram - Fig. 9
Terminals
Connection
1
L
230 V power supply
2
N
3
Earth
4
5
N
230 V lighting
output
6
L
7
Contact
Auxiliary contact
output
8
Shared
9
0 V
9 V low-voltage
power supply input
10 9 V
11 +
Motor 1
12 -
13 End limit
Ixengo only
14 +
Motor 2
15 -
16 End limit
Ixengo only
17 24 V - 15 W
24 V - 15 W orange
light
18 0 V
19 24 V
24 V accessories
power supply
20 0 V
21 24 V
Safety device
power supply
22 0 V
23 Shared
Safety input 1 -
Cells
24 Contact
25 +
24 V lock or 12 V
lock output
26 -
EN
Comments
Max. power 500 W
Protected by 5A time-delay
fuse
Dry contact for 24V, 2A max,
Safety Extra Low Voltage
(SELV)
At 9 V, degraded operation
1.2 A max for all accessories
on all outputs
Permanent if autotest not se-
lected, controlled if autotest
selected
Used to connect RX receiver
cell
BUS compatible (see param-
eter table)
Programmable (parameter
P17)
4