Télécharger Imprimer la page

Meade Instruments 7 LX200 Serie Mode D'emploi page 70

Publicité

commands except ":Q#" and ":h?#" are disabled during
the search.
Command
:hP#
Returns
Nothing
Slews the telescope to the home position.
Command
:h?#
Returns
0, 1, or 2
Returns the home status: 0 if home search failed or not
yet attempted, 1 if home position found, or 2 if a home
search is in progress.
e. Library/Objects
Command
:Gr#
Returns
HH:MM.T#
Gets object right ascension.
Command
:Sr HH:MM.T#
Returns
Ok
Sets object right ascension.
Command
:Gd#
Returns
sDD*MM#
Gets object declination.
Command
:Sd sDD*MM#
Returns
Ok
Sets object declination.
Command
:Sa sDD*MM#
Returns
Ok
Sets object altitude (for MA command).
Command
:Sz DDD*MM#
Returns
Ok
Sets object azimuth (for MA command).
Command
:CM#
Returns
(see description)
Sync. Matches current telescope coordinates to the
object coordinates and sends a string indicating which
object's coordinates were used.
Command
:Gy#
Returns
GPDCO#
Gets the "type" string for the FIND operation. A capital
letter means that the corresponding type is selected while
a lower case letter indicates it is not.
Command
:Sy GPDCO#
Returns
Ok
Sets the "type" string for the FIND operation.
Command
:Gq#
Returns
SU#, EX#, VG#, GD#, FR#, PR#, or VP#
Gets the current minimum quality for the FIND operation.
Command
:Sq#
Returns
Nothing
Steps to the next minimum quality for the FIND operation.
Command
:Gh#
Returns
DD*#
Gets the current "higher" limit.\
Command
:Sh DD#
Returns
Ok
Sets the current "higher" limit.
Command
:Go#
Returns
DD*#
Gets the current "lower" limit.
Command
:So DD*#
Returns
Ok
Sets the current "lower" limit.
Command
:Gb#
:Gf#
Returns
sMM.M#