Installation diagram
Distance from wall
should be over 50mm
Indoor unit
Distance from Рoor
should be over 2500mm
Outdoor unit
Air intake distance from the
wall should be over 250mm
When install interconnection cord , make sure that the color of wires and the terminal No. of outdoor unit shall be
same as those in indoor unit.
Cable Specifications
Capacity (Btu/h)
7K, 9K, 12K
18K
24 K
All manuals and user guides at all-guides.com
Distance from ceiling
should be over 200mm
Power cord
Normal cross -
Type
sectional area
- 17 -
H07RN-F
1.0mm
H07RN-F
1.5mm
H07RN-F
2.5mm
To get detail installation information ,
please go to : docs.whirlpool.eu
Distance from the wall
should be over 50mm
NOTE: The Čgure is only a simple
presentation of the unit, it may not mutch
the external appearance of the product you
purchased. Installation must be performed in
accordance with th national wiring standard
by authurized service people only.
Air intake distance from the
wall should be over 250mm
Over 250mm
Power connecting cord
Type
X3
H07RN-F
2
X3
H07RN-F
2
X3
H07RN-F
2
Normal cross -
sectional area
1.0mm
X5
2
1.5mm
X5
2
2.5mm
X5
2