2.6 Control parameters and display channels
Channel
ANL
x
x
S3
x
Temperature sensor 3
S4
x
Temperature sensor 4
TRL
x
Temperatur Rücklauf
h P
x
Hours run, relay 1
x
x
S MX
x
NOT
x
Collector emergency stop
OKK
x
x
OSYK
x
Option System cooling
DTKE
x*
System cooling, Start temperature differential
DTKA
x*
System cooling, Stop temperature differential
OSPK
x
Option, Cylinder cooling
OURL
x
Option, Holiday cooling
TURL
x*
Temperature for holiday cooling
KMN
x*
x
Collector frost protection option
x*
Collector frost protection temperature
ORK
x
Tube collector option
RKAN
x*
RKEN
x*
Tube collector function, End
RKLA
x*
Tube collector function, Runtime
RKSZ
x*
Tube collector function, Idle period
HND
x
Manual mode, relay 1
SPR
x
OWMZ
x
Option WMZ
VMAX
x*
Maximum throughput
MEDT
x*
Type of frost protection
MED%
x*
Anti-freeze content
MWh
x*
Heat amount MWh
kWh
x*
Heat amount kWh
ODB
x
INIT
x*
Display of the remaining time, Start condition
FLL
x*
Display of the remaining time, Filling process
STAB
x*
Display of the remaining stabilisation time
tFLL
x*
Filling time of the Drainback function
VERS
X.XX Version number
RESE
x
Reset to factory settings
EINH
x
Temperature unit
Legend
Appropriate channel is available.
x
Appropriate channel is available subject to the associated option being enabled.
x*
Note: S3 and S4 are only displayed if the temperature sensors are connected (superimposed)
Description
Factory setting
Display/setting range
-40 ... +260 °C
-40 ... +260 °C
6 K
1,0 ... 20,0 K
60 °C
4 ... 95 °C
130 °C
80 ... 200 °C
OFF
OFF ... ON
110 °C
OFF
OFF
OFF / ON
20 K
1,0...30,0 K
15 K
0,5...29,5 K
OFF
OFF / ON
OFF
OFF / ON
25 °C
OFF
OFF
OFF ... ON
4 °C
-10 ... 10 °C
OFF
OFF ... ON
07:00
00:00 ... 23:45
19:00
00:00 ... 23:45
30 Sek.
5 ... 500 Sek.
30 Min.
1 ... 60 Min.
AUTO
DE
DE, EN, FR, IT
OFF
OFF /ON
6
0,5 ... 100
1
0 ... 3
45
20 ... 70
OFF
OFF/ON
1 ... 30 min
2 min
°C
°C / °F
23