2.6.1 Display: Collector temperatures
KOL :
Collector temperature
Display range: -40 ... +260 °C
2.6.2 Display: Cylinder temperature
TSP:
Cylinder temperatures
Display range:
-40... +260 °C
2.6.3 Display Sensor 3
S3, S4:
Sensor temperature
Display range:
-40...+260 °C
2.6.4 Display current pump speed
n%: Current pump speed
Display range: 30 ... 100 %
2.6.5 Display of the drainback periods
INIT: Drainback
initialisation active
FLL: Drainback filling time
active
STAB: Drainback
stabilisation
2.6.6 Hours run meter
h P: Hours run meter
Display channel
2.6.7 Heat meter statement
OWMZ: Heat statement
Setting range OFF ... ON
Factory setting OFF
VMAX: Flow rate in
l/min
Setting range 0 ...20
in 0.1 steps
Factory setting 6.0
24
Shows the current collector temperature:
*.+
• KOL
°C
Shows the current cylinder temperature:
32/
• TSP
°C
Shows the current temperature of the additional sensor (without control function).
2
Note:
°C
S3 is only shown when the temperature sensor is connected (superimposed)
Shows the current speed of the respective pump.
n%
The SOKI must be set to stage 3 to use the variable speed control function.
Display of the remaining period for Drainback initialisation
(-(3
Display of the remaining period for Drainback filling time
%++
Display of the remaining period for Drainback stabilisation
23 !
The hours run meter adds up the hours of solar operation of the relay (h P). Full
hours are shown on the display.
The accumulated hours run can be reset. As soon as the hours run channel is
selected, symbol
pushbutton for approx. 2 seconds to access the counter RESET mode. The display
symbol
process, confirm with
To cancel the RESET process, do not press any pushbutton for approx. 5 seconds.
The controller will then automatically revert to display mode.
Heat metering is available in conjunction with a flow meter. For this, enable the
.6,9
"heat statement" option in channel OWMZ.
.%%
SET
The flow rate (l/min) to be checked on the flow meter must be set in channel
5, 7
VMAX. The type of frost protection and the antifreeze content of the heat transfer
SET
medium are specified in channels MEDT and MED%.
°C
: Collector temperature
: Cylinder temperature
: Current pump speed (single pump system)
appears permanently in the display. Hold down the SET (3)
SET
flashes and the hours run are reset to 0. To complete the RESET
SET
.
SET